Degree of Conversion of Self-etch Adhesives: In Situ Micro-Raman Analysis
Purpose:
Degree of conversion (DC) affects the physicochemical properties of dental adhesives. The aim of this study was to measure the DC within the hybrid layer of four one-step self-etch adhesives using Raman microspectroscopy. The hypothesis tested was that there was no difference among the tested adhesives.
Methods And Materials:
The selected one-step self-etch adhesives (Clearfil S3 Bond Plus, I-BOND, G-BOND, and Adper Easy Bond) were applied on human dentin disks and polymerized in accordance with the manufacturers' instructions. Specimens were transversally cut to expose the bonded interfaces to the micro-Raman beam, and Raman spectra were collected along the dentin/adhesive interface. Measurements were performed at 1-μm intervals. The relative intensities of bands associated with the C=C bond (at 1640 cm-1) and an internal stable peak (1610 cm-1) were determined to calculate the degree of conversion within the hybrid layer. Data were statistically analyzed with Kolmogorov-Smirnov and Bartlett tests and Kruskal-Wallis and Mann-Whitney U-tests.
Results:
The DC ranked as follows: G-BOND (93%±6%) ≥ Adper Easy Bond (92%±6%) ≥ I-BOND (89%±7%) > Clearfil S3 Bond Plus (80%±14%) (p<0.05).
Conclusions:
Based on the results of this study, all of the tested self-etch adhesives showed a clinically acceptable DC that was material dependent.
Related Concept Videos
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...