Data on comparison between FLEC and CLIMPAQ methods used for fast sorption measurements of VOCs on building materials
Malak Rizk1, Marie Verriele2, Maxence Mendez3
1Mines Douai, SAGE, F-59508 Douai, France; Université de Lille, F-59000 Lille, France; Université de Strasbourg/CNRS. Institut de Chimie et Procédés pour l'Energie, l'Environnement et la Santé (ICPEES), UMR 7515, F-67087 Strasbourg, France.
Abstract:
A test emission chamber called CLIMPAQ has been coupled to a chromatography analyzer GC to measure volatile organic compounds (VOC) concentration during a sorption experiments (Fast sorption measurements of VOCs on building materials: Part 2 - Comparison between FLEC and CLIMPAQ methods, (Rizk et al., In press) [1]). The equations used to calculate the mass transfer coefficient and the thickness of the boundary layer developed on the surface of a material are presented. In addition, the experimental profiles obtained using the CLIMPAQ chamber is also presented in the presence and the absence of a building material. Finally, the impact of chamber size on the obtained concentration profile using different chambers is shown using 3 types of chambers having different volumes, 1 m(3), 30 m(3) and a micro chamber of 40 mL.