Related Experiment Video
Updated: Jul 16, 2026

Non-contact, Label-free Monitoring of Cells and Extracellular Matrix using Raman Spectroscopy
Published on: May 29, 2012
Multi-centre Raman spectral mapping of oesophageal cancer tissues: a study to assess system transferability
M Isabelle1, J Dorney2, A Lewis3
1Biophotonics Research Unit and Pathology Department, Gloucestershire Hospitals NHS Foundation Trust, Gloucester, UK. martini_30@hotmail.com.
Abstract:
The potential for Raman spectroscopy to provide early and improved diagnosis on a wide range of tissue and biopsy samples in situ is well documented. The standard histopathology diagnostic methods of reviewing H&E and/or immunohistochemical (IHC) stained tissue sections provides valuable clinical information, but requires both logistics (review, analysis and interpretation by an expert) and costly processing and reagents. Vibrational spectroscopy offers a complimentary diagnostic tool providing specific and multiplexed information relating to molecular structure and composition, but is not yet used to a significant extent in a clinical setting. One of the challenges for clinical implementation is that each Raman spectrometer system will have different characteristics and therefore spectra are not readily compatible between systems. This is essential for clinical implementation where classification models are used to compare measured biochemical or tissue spectra against a library training dataset. In this study, we demonstrate the development and validation of a classification model to discriminate between adenocarcinoma (AC) and non-cancerous intraepithelial metaplasia (IM) oesophageal tissue samples, measured on three different Raman instruments across three different locations. Spectra were corrected using system transfer spectral correction algorithms including wavenumber shift (offset) correction, instrument response correction and baseline removal. The results from this study indicate that the combined correction methods do minimize the instrument and sample quality variations within and between the instrument sites. However, more tissue samples of varying pathology states and greater tissue area coverage (per sample) are needed to properly assess the ability of Raman spectroscopy and system transferability algorithms over multiple instrument sites.
More Related Videos
10:37A Multimodal Imaging Framework to Advance Phenotyping of Living Label-free Breast Cancer Cells
Published on: August 22, 2025
06:58Exploring the Application of Surface-enhanced Raman Scattering-based Biosensing of Individual sEVs in Disease Diagnosis and Therapeutics
Published on: March 13, 2026
Related Concept Videos
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and the...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...