Transcutaneous closure of chronic broncho-pleuro-cutaneous fistula by duct occluder device
Vikas Marwah1, R Ravikumar2, Ashok Kumar Rajput1
1Department of Respiratory Medicine, Army Hospital (Research and Referral), Delhi, India.
Abstract:
Bronchopleural fistula (BPF) is a well known complication of several pulmonary conditions posing challenging management problem and is often associated with high morbidity and mortality. Though no consensus exists on a definite closure management algorithm, strategies for closure widely include various methods like tube thoracostomy with suction, open surgical closure, bronchoscopy directed glue, coiling and sealants which now also includes use of occlusion devices. We report a case in which a novel method of delivery and closure of recurrent post-operative broncho-pleuro-cutaneous fistula by a duct occluder device was done transcutaneously which has not been previously described in literature.