Related Experiment Video
Updated: Mar 23, 2026

An Experimental Human DIEP Flap Model to Investigate Preservation Strategies for Vascularized Composite Allografts and Free Flaps
Published on: December 5, 2025
Herniation after deep circumflex iliac artery flap: two cases of rare complication
Hee-Sung Kim1, Jae-Young Kim2, Hyuk Hur3
1Department of Oral and Maxillofacial Surgery, Yonsei University College of Dentistry, Yonsei-ro 50, Seodaemun-gu, Seoul, 120-752 Korea.
Abstract:
Herniation after harvesting of deep circumflex iliac artery (DCIA) flap is a known but not a common complication. It occurs about 2.8 to 9 % according to the literatures and can proceed to a more severe complication such as bowel obstruction. There are several factors that exacerbate the risk: surgical factors, operator factor, and patient factors. Surgical factors include large anatomical defect and denervation of related muscles. Operator factor stands for unpunctual suture technique. Patient factors represent obesity, diabetes, pulmonary disease, smoking habits, and so on. Thus, herniation might occur regardless of meticulous suture. Herein, we would like to report two cases of herniation after DCIA flap harvesting and repaired by Lichtenstein tension-free hernioplasty with literature review.