Related Experiment Video
Updated: Mar 22, 2026

Hyperpolarized Xenon for NMR and MRI Applications
Published on: September 6, 2012
Establishing an accurate gas phase reference frequency to quantify 129 Xe chemical shifts in vivo
Rohan S Virgincar1,2, Scott H Robertson1,3, John Nouls1,4
1Center for In Vivo Microscopy, Duke University Medical Center, Durham, North Carolina, USA.
Purpose:
129 Xe interacts with biological media to exhibit chemical shifts exceeding 200 ppm that report on physiology and pathology. Extracting this functional information requires shifts to be measured precisely. Historically, shifts have been reported relative to the gas-phase resonance originating from pulmonary airspaces. However, this frequency is not fixed-it is affected by bulk magnetic susceptibility, as well as Xe-N2 , Xe-Xe, and Xe-O2 interactions. In this study, we addressed this by introducing a robust method to determine the 0 ppm 129 Xe reference from in vivo data.
Methods:
Respiratory-gated hyperpolarized 129 Xe spectra from the gas- and dissolved-phases were acquired in four mice at 2T from multiple axial slices within the thoracic cavity. Complex spectra were then fitted in the time domain to identify peaks.
Results:
Gas-phase 129 Xe exhibited two distinct resonances corresponding to 129 Xe in conducting airways (varying from -0.6 ± 0.2 to 1.3 ± 0.3 ppm) and alveoli (relatively stable, at -2.2 ± 0.1 ppm). Dissolved-phase 129 Xe exhibited five reproducible resonances in the thorax at 198.4 ± 0.4, 195.5 ± 0.4, 193.9 ± 0.2, 191.3 ± 0.2, and 190.7 ± 0.3 ppm.
Conclusion:
The alveolar 129 Xe resonance exhibits a stable frequency across all mice. Therefore, it can provide a reliable in vivo reference frequency by which to characterize other spectroscopic shifts. Magn Reson Med 77:1438-1445, 2017. © 2016 International Society for Magnetic Resonance in Medicine.
Related Concept Videos
Chemical Shift: Internal References and Solvent Effects
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...
NMR Spectroscopy: Chemical Shift Overview
For instance, the proton...
Other Nuclides: 31P, 19F, 15N NMR
While fluorine-19 and phosphorous-31 have high natural abundances (100%) and positive gyromagnetic ratios, nitrogen-15 has a low natural abundance and a negative gyromagnetic ratio. However, nitrogen-15 is still preferred over nitrogen-14 (which has a...
Carbon-13 (¹³C) NMR: Overview
¹³C NMR: ¹H–¹³C Decoupling
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are...