Abstract:
Surgical optimization of the cavopulmonary connection and pharmacological therapy for dysfunctional Fontan physiology continue to advance, but these treatment approaches only slow the progression of decline to end-stage heart failure. The development of a mechanical cavopulmonary assist device will provide a viable therapeutic option in the bridging of patients to transplant or to stabilization. We hypothesize that rotational blood flow, delivered by an implantable axial flow blood pump, could effectively assist the venous circulation in Fontan patients by mimicking vortical blood flow patterns in the cardiovascular system. This study investigated seven new models of mechanical cavopulmonary assistance (single and dual-pump assist), created combinations of pump designs that deliver counter rotating vortical flow conditions, and analyzed pump performance, velocity streamlines, swirling strength, and energy augmentation in the cavopulmonary circuit for each support scenario. The model having an axial clockwise-oriented impeller in the inferior vena cava and an axial counterclockwise-oriented impeller rotating in the superior vena cava outperformed all of the support scenarios by enhancing the energy of the cavopulmonary circulation an average of 10.3% over the entire flow range and a maximum of 27.4% at %the higher flow rates. This research will guide the development of axial flow blood pumps for Fontan patients and demonstrated the high probability of %a cardiovascular benefit using counter rotating pumps in a dual support scenario, but found that this is dependent upon the patient-specific cavopulmonary anatomy.
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
General External Flow Characteristics
Mechanical Ventilation I: Indication and Settings
Turbulent Flow