Related Experiment Video
Updated: Mar 22, 2026

Author Spotlight: Advancements in Refractive Surgical Correction for Presbyopia and Exploring Postoperative Visual Acuity
Published on: September 20, 2024
Keratoconus correction using a new model of intrastromal corneal ring segments
Marina Israel1, Mohamed O Yousif1, Nermin A Osman1
1From the Department of Ophthalmology (Israel, Yousif, Nashed), Faculty of Medicine, Ain Shams University, Cairo, and the Medical Research Institute (Osman), Alexandria University, Alexandria, Egypt; the Doheny Image Reading Center (Abdelfattah), Doheny Eye Institute, and the Department of Ophthalmology (Abdelfattah), David Geffen School of Medicine, University of California Los Angeles, California, USA.
Purpose:
To evaluate the optical value of a new model of intrastromal corneal ring segments (ICRS) (Keratacx Plus) in patients with keratoconus and to quantify subsequent changes in corneal topography and asphericity.
Setting:
Private practice.
Design:
Prospective case series.
Methods:
This study comprised patients who had primary keratoconus or keratectasia after laser in situ keratomileusis (LASIK); none wore contact lenses. Rings were implanted through tunnels created manually or with a femtosecond laser. All eyes had clear visual axes and corneal thickness over 450 μm at the incision site. Preoperative and postoperative pachymetry images were acquired. Results were analyzed using a matched-pair t test and the Kolmogorov-Smirnov test.
Results:
Twenty-nine eyes (24 patients; mean age 30.1 years ± 10.6 [SD]) were evaluated. The ICRS significantly increased uncorrected and corrected visual acuities from 0.05 to 0.16 and from 0.17 to 0.5, respectively (z = 4.7, P < .001). They reduced the median spherical error from -4.0 to -0.5 diopters (D) (P < .001) and median cylindrical error from -4.4 to -2.5 D (P < .001). All topographic parameters were reduced, including maximum keratometry (K) (49.4 D versus 45.1 D), minimum K (49.4 D versus 45.1 D), mean K (51.4 D versus 48.4 D), astigmatism (-2.0 D versus -0.5 D), and asphericity (eccentricity 0.49 versus 0.23) (all P < .001).
Conclusions:
The ICRS provided topographic and visual improvement in keratoconus and post-LASIK keratectasia. Variance in surgical outcomes with manual versus femtosecond tunneling and the effect of different ring sizes are yet to be studied.
More Related Videos
07:29Three Different Protocols of Corneal Collagen Crosslinking in Keratoconus: Conventional, Accelerated and Iontophoresis
Published on: November 12, 2015
11:42Combination of Microstereolithography and Electrospinning to Produce Membranes Equipped with Niches for Corneal Regeneration
Published on: September 12, 2014
Related Concept Videos
Focusing of Light in the Eye
Angle Closure Glaucoma: Treatment