Use of smartphone attached mobile thermography assessing subclinical inflammation: a pilot study
T Kanazawa1, G Nakagami1, T Goto1
1Department of Gerontological Nursing/Wound Care Management, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan.
Objective:
To verify the reliability and validity of FLIR ONE, a device connected to a smartphone, for the assessment of inflammation based on relative temperature increase compared with the thermography routinely used in pressure ulcer (PU) and diabetic foot assessment.
Method:
Participants in this pilot cross-sectional observational study were recruited from the patients in the PU team rounds and the diabetic foot outpatient clinic at the university hospital in January 2015. Cohen's kappa coefficient with its 95% confidence intervals was used to evaluate the criterion-related validity and inter- and intra-rater reliability for the thermal imaging assessment. For assessing criterion-related validity, a hand-held high-end infrared thermography device was used to provide reference data. Comparison of thermal images between the smartphone-connected device and the hand-held device was performed with both a 'predetermined range' and an 'automatically-set range.' For assessing inter-rater reliability, two assessors evaluated the thermal images taken by the mobile thermography. For assessing intra-rater reliability, one assessor evaluated the thermal images twice. The thermal images were shown to the assessors at random.
Results:
Among 16 thermal images obtained from eight patients, kappa coefficients for each value were as follows: for the predetermined range and automatically-set range, respectively, the criterion-related validity was 1.00 (95% confidence interval 1.00-1.00) and 1.00 (95% confidence interval 1.00-1.00); the inter-rater reliability was 1.00 (95% confidence interval 1.00-1.00) and 1.00 (95% confidence interval 1.00-1.00); and the intra-rater reliability was 1.00 (95% confidence interval 1.00-1.00) and 1.00 (95% confidence interval 1.00-1.00).
Conclusion:
This pilot study suggests that FLIR ONE can work as an alternative device for assessing subclinical inflammation in PUs and the diabetic foot in clinical settings. Our results may facilitate clinicians in accepting the routine use of thermal imaging assessment at the patients' bedside.
Related Concept Videos
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...