Systematic Review of the Exposure Assessment and Epidemiology of High-Frequency Voltage Transients

Frank de Vocht1, Robert G Olsen2

  • 1School of Social and Community Medicine, University of Bristol , Bristol , UK.

Related Concept Videos

Applications of EMF Measurements01:26

Applications of EMF Measurements

Electromotive force (EMF) measurements have a broad range of applications in various fields, including chemistry and physics. The electrochemical series, an arrangement of elements in order of their standard electrode potentials, can be determined through EMF measurements. Elements with lower standard potentials can reduce ions of elements with higher standard potentials.The standard cell potential, E°, allows for the calculation of the standard reaction Gibbs energy, ΔG°, and...
41
Series R—L Circuit Transients01:22

Series R—L Circuit Transients

In a series resistor-inductor (R-L) circuit, closing the switch at the start of the time period simulates a three-phase short circuit, a fault condition where all three phases of an unloaded synchronous machine are short-circuited. When there is no fault impedance and no initial current, the initial voltage is determined by the phase angle of the source voltage.
Using Kirchhoff's Voltage Law (KVL) to analyze this circuit helps determine the total asymmetrical fault current, which consists...
481
Power System Three-Phase Short Circuits01:21

Power System Three-Phase Short Circuits

Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
623
Lossy Lines and Overvoltages01:22

Lossy Lines and Overvoltages

Transmission-line series resistance and shunt conductance cause three primary effects: attenuation, distortion, and power losses.
Attenuation
When constant series resistance and shunt conductance are present, voltage and current equations are modified. The propagation constant indicates that voltage and current waves consist of both forward and backward traveling components. These waves attenuate as they propagate, with the attenuation factor related to the resistance and conductance. In a...
385