Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Bioavailability Study Design: Single Versus Multiple Dose Studies01:11

Bioavailability Study Design: Single Versus Multiple Dose Studies

220
Bioavailability studies are essential for understanding how a drug is absorbed, distributed, metabolized, and excreted in the body. These studies assess the extent and rate at which the active pharmaceutical agent becomes available at the site of action. The design of bioavailability studies can involve single-dose or multiple-dose regimens, each with distinct advantages and limitations.Single-dose studies are the preferred approach due to their simplicity and reduced drug exposure for...
220
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT01:25

Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT

436
Calcium-Scoring CT ScanA calcium-scoring CT scan, also known as coronary artery calcium (CAC) scan, detects calcium deposits in the coronary arteries. This test assesses the risk of coronary artery disease (CAD), which can lead to cardiovascular events such as angina, heart failure, and sudden cardiac arrest.A calcium-scoring CT scan is generally recommended for individuals at intermediate risk of CAD without symptoms. It includes:Men aged 40-75 and women aged 50-75: Especially those with a...
436
Imaging Studies for Cardiovascular System V: CT01:28

Imaging Studies for Cardiovascular System V: CT

326
Cardiac computed tomography (CT) scanning is an advanced cardiac imaging technique that utilizes CT technology, with or without intravenous (IV) contrast, to produce accurate cross-sectional virtual slices of specific areas of the heart, coronary circulation, and major blood vessels such as the aorta, pulmonary veins, and arteries. The computer processes these slices to generate three-dimensional images. Multidetector CT (MDCT) is a rapid form of CT scanning that captures multiple slices...
326
Biological Effects of Radiation02:59

Biological Effects of Radiation

17.7K
All radioactive nuclides emit high-energy particles or electromagnetic waves. When this radiation encounters living cells, it can cause heating, break chemical bonds, or ionize molecules. The most serious biological damage results when these radioactive emissions fragment or ionize molecules. For example, α and β particles emitted from nuclear decay reactions possess much higher energies than ordinary chemical bond energies. When these particles strike and penetrate matter, they...
17.7K
Imaging Studies I: CT and MRI01:14

Imaging Studies I: CT and MRI

839
Introduction: MRI and CT scans are crucial advancements in medical imaging techniques, playing a vital role in diagnosing conditions related to the gastrointestinal (GI) system. Each scan serves distinct purposes, targets specific areas, and requires unique nursing duties.
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
839
Oxidation-Reduction Reactions03:11

Oxidation-Reduction Reactions

75.2K
Oxidation–Reduction Reactions
75.2K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Commentary: Foreword From the Editor-in-Chief for Guest Section on Low Field Strength MRI.

Journal of computer assisted tomography·2026
Same author

Imaging of De Novo Malignancy after Solid Organ Transplant.

Radiology·2026
Same author

Quantitative Imaging of Pyruvate Metabolism in a Patient With Anaplastic Thyroid Cancer.

Magnetic resonance in medicine·2026
Same author

Fluorescence Imaging of DMDG-ICG Across NIR-I and NIR-II Windows Using a Single-Camera System.

International journal of molecular sciences·2026
Same author

Evaluating the Cost-Effectiveness of PSMA PET Should Benefit From Additional Research.

AJR. American journal of roentgenology·2026
Same author

Correlation of Automated in Vivo Image Quality With Radiologist's Performance in Abdomen Computed Tomography Across Conventional and Deep Learning Reconstructions.

Journal of computer assisted tomography·2026

Related Experiment Video

Updated: Jan 25, 2026

Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
07:57

Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform

Published on: March 24, 2022

3.1K

Performance evaluation of iterative reconstruction algorithms for achieving CT radiation dose reduction - a phantom

Cristina T Dodge1, Eric P Tamm, Dianna D Cody

  • 1The University of Texas MD Anderson Cancer Center. cpalcu@yahoo.com.

Journal of Applied Clinical Medical Physics
|April 14, 2016
PubMed
Summary

Model-based iterative reconstruction (MBIR) significantly enhances CT image quality and low-contrast detectability at low doses compared to adaptive statistical iterative reconstruction (ASiR) and filtered back-projection (FBP). MBIR shows potential for substantial radiation dose reduction in patient imaging.

More Related Videos

Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
06:20

Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition

Published on: March 11, 2021

7.7K
X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
08:30

X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging

Published on: September 11, 2011

14.8K

Related Experiment Videos

Last Updated: Jan 25, 2026

Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
07:57

Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform

Published on: March 24, 2022

3.1K
Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
06:20

Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition

Published on: March 11, 2021

7.7K
X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
08:30

X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging

Published on: September 11, 2011

14.8K

Area of Science:

  • Medical Imaging
  • Radiology
  • Image Reconstruction

Background:

  • Iterative reconstruction techniques (IRTs) in CT aim to improve image quality while reducing radiation dose.
  • Adaptive statistical iterative reconstruction (ASiR) and model-based iterative reconstruction (MBIR) are advanced IRTs offered by GE.
  • Quantitative characterization of their performance across dose levels is crucial for clinical implementation.

Purpose of the Study:

  • To quantitatively evaluate and compare image quality and dose performance of GE's ASiR and MBIR techniques against filtered back-projection (FBP).
  • To assess the advantages and limitations of these reconstruction methods across a range of typical to low radiation doses.
  • To determine the potential for dose reduction with these advanced techniques.

Main Methods:

  • Utilized Catphan 600 and anthropomorphic Kyoto Kagaku abdomen phantoms.
  • Scanned using a GE Discovery HD750 scanner at varying pitch factors and CTDIvol levels (1-24 mGy).
  • Images reconstructed with FBP, 20-70% ASiR, and MBIR; evaluated noise, contrast-to-noise ratio (CNR), Hounsfield units (HUs), and modulation transfer function (MTF).

Main Results:

  • MBIR demonstrated a five-fold reduction in noise and a five-fold increase in CNR compared to FBP below 6 mGy CTDIvol.
  • MBIR exhibited superior spatial resolution and improved conspicuity of high-contrast details.
  • ASiR and FBP showed less sensitivity to dose and pitch changes, while MBIR's spatial resolution improved with increasing dose and pitch.

Conclusions:

  • MBIR offers substantial improvements in image quality and low-contrast detectability, particularly at low radiation doses (around 1 mGy CTDIvol).
  • MBIR and ASiR show potential for significant radiation dose reduction in clinical CT protocols.
  • Quantitative analysis confirms MBIR's advantages over ASiR and FBP, especially in low-dose scenarios.