Right heart catheterisation may be cautiously performed through a mechanical valve prosthesis in the tricuspid
Stephen Pettit1, Steven Tsui1, Jayan Parameshwar1
1Transplant Unit, Papworth Hospital NHS Foundation Trust, Cambridge, UK.
Abstract:
Right heart catheterisation (RHC) may be performed through a mechanical valve prosthesis in the tricuspid position using a partially inflated pulmonary artery flotation catheter. Preprocedural preparation should include an ex vivo trial with an identical valve prosthesis and the type of catheter to be used for the procedure. The operator should expect immediate unloading of the right ventricle due to catheter-associated tricuspid regurgitation, but it is possible to estimate pulmonary vascular resistance using the Fick principle. The risk of catheter entrapment or damage to the prosthetic leaflets during the procedure is likely to be low. This risk may be acceptable to the clinician and the patient if pulmonary vascular resistance must be measured in order to determine eligibility for heart transplantation.
More Related Videos
05:31Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
09:57Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022
Related Concept Videos
Cardiac Catheterization III: Left Heart Catheterization
Mitral Stenosis III: Medical Management
Cardiac Catheterization II: Right Heart Catheterization
Cardiac Catheterization I: Pre-Procedure Overview
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...