Related Experiment Video
Updated: Mar 22, 2026

Esophageal Heat Transfer for Patient Temperature Control and Targeted Temperature Management
Published on: November 21, 2017
Analytical and subjective interpretation of thermal comfort in hospitals: A case study in two sterilization services
Carlos Carvalhais1,2, Joana Santos1,2, Manuela Vieira da Silva1,2
1a Environmental Health Department , School of Allied Health Technologies of Polytechnic Institute of Porto (ESTSP.IPP) , Vila Nova de Gaia , Portugal.
Abstract:
Hospital facilities are normally very complex, which combined with patient requirements promote conditions for potential development of uncomfortable working conditions. Thermal discomfort is one such example. This study aimed to determine levels of thermal comfort, sensations, and preferences, from a field investigation conducted in two sterilization services (SS) of two hospitals from Porto and Aveiro, Portugal. The analytical determination and interpretation of thermal comfort was based upon assumptions of ISO 7726:1998 and ISO 7730:2005. The predicted mean vote (PMV) and predicted percentage of dissatisfaction (PPD) indices were obtained by measurement and estimation of environmental and personal variables, respectively, and calculated according to ISO 7730 equations. The subjective variables were obtained from thermal sensation (subjective PMV) and affective assessment (subjective PPD), reported by a questionnaire based upon ISO 10551:1995. Both approaches confirmed thermal discomfort in both SS (codified as SS1 and SS2). For all areas, PMV and PPD exceeded in all periods of the day the recommended range of -0.5 to +0.5 and <10%, respectively. No significant differences were found between day periods. The questionnaire results showed that SS2 workers reported a higher level of thermal discomfort. There were no significant differences between PMV and thermal sensations, as well as between PPD and affective assessment. The PMV/PPD model was found suitable to predict thermal sensations of occupants in hospital SS located in areas with a mild climate in Portugal.
Related Concept Videos
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Physical Methods for Controlling Microbial Growth: Temperature

