Related Experiment Video
Updated: Mar 22, 2026

Repeated Measurement of Respiratory Muscle Activity and Ventilation in Mouse Models of Neuromuscular Disease
Published on: April 17, 2017
Patient-ventilator asynchrony, leaks and sleep in patients with amyotrophic lateral sclerosis
Bart Vrijsen1,2, Dries Testelmans1,3, Catharina Belge1,3
1a Department of Pulmonology and Leuven University Centre for Sleep and Wake disorders (LUCS) - University Hospitals Leuven .
Abstract:
Sleeping with non-invasive ventilation (NIV) in amyotrophic lateral sclerosis appears to be accompanied by a high patient-ventilator asynchrony (PVA) index. This prospective observational cohort study quantifies PVA and leaks, and searches for effects of these events on sleep after polysomnographic NIV titration. Full-video polysomnography, with incorporation of transcutaneous carbon dioxide and ventilator software, was used to analyse sleep epoch-by-epoch and respiratory events and PVA breath-by-breath in 35 patients (17 non-bulbar). After diagnostic polysomnography, NIV was titrated during three consecutive nights. Sleep, PVA and leaks were evaluated at discharge and after one month. Results showed that non-bulbar patients improved in sleep architecture and oxygen and carbon dioxide levels while bulbar patients only improved oxygen saturation. PVA remained present at discharge (non-bulbar 54 (21-101) and bulbar 31 (9-39)/h sleep) and one month (non-bulbar 31 (9-39) and bulbar 32 (17-55)/h sleep), with ineffective effort as most prominent asynchrony. Leaks also persisted after titration (non-bulbar 16.6 (3.1-44.6) and bulbar 5.1 (0.0-19.5)% of total sleep time (TST)) and one month (non-bulbar 7.7 (1.4-29.3) and bulbar 12.7 (0.0-35.2)% TST). PVA and leaks have none to minor effect on sleep architecture. In conclusion, although PVA and leaks remain present after meticulous NIV titration, these events seem not to interfere with sleep.
More Related Videos
Related Concept Videos
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Mechanical Ventilation I: Indication and Settings
Sleep Apnea
The condition is more prevalent among...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...