Related Experiment Video
Updated: Mar 22, 2026

Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capnography Monitor
Published on: September 29, 2020
Arterial pressure, end-tidal carbon dioxide, and central venous oxygen saturation in reflecting compression depth
1Department of Emergency Medicine, Chonnam National University Hospital, Gwangju, Korea.
Background:
We sought to investigate the utility of arterial pressure, end-tidal carbon dioxide (ETCO2 ), and central venous oxygen saturation (SCVO2 ) to guide compression depth adjustment. Thus, in a pig model of cardiac arrest, we observed these parameters during cardiopulmonary resuscitation (CPR) with optimal and suboptimal compression depths.
Methods:
Sixteen pigs underwent three experimental sessions after induction of ventricular fibrillation. First, the animals received two 4-min CPR trials with either optimal (20% of the anteroposterior diameter) or suboptimal (70% of the optimal depth) compression depth. Second, the animals received two 5-min CPR trials with optimal compression depth, in which adrenaline (0.02 mg/kg) or saline placebo was administered. Third, the animals randomly received compression with either optimal or suboptimal depth during advanced cardiovascular life support.
Results:
The systolic arterial pressure reflected compression depth most accurately and immediately (area under the curve [AUC], 0.895-0.939 without adrenaline and 0.928-1.000 with adrenaline). Although the response of ETCO2 to the change in compression depth was 0.5 min slower than that of the systolic arterial pressure, the performance of ETCO2 was comparable with that of systolic arterial pressure. SCVO2 did not reflect compression depth. Adrenaline administration remarkably increased systolic arterial pressure, diastolic arterial pressure, and coronary perfusion pressure but did not affect the ETCO2 readings.
Conclusion:
In a pig model of cardiac arrest, systolic arterial pressure reflected compression depth immediately and accurately. The performance of ETCO2 was comparable with that of systolic arterial pressure. SCVO2 did not reflect compression depth.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
07:52Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 29, 2011
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Chemical Factors Affecting Respiration Centers
CO2 has a potent influence on respiration and is strictly regulated....
Blood Studies I: ABG and VBG
Arterial Blood Gas (ABG)
Arterial Blood Gas (ABG) studies are crucial for assessing the lungs' ability to supply oxygen and remove carbon dioxide, reflecting the patient's ventilation status. They also help understand the kidneys' capacity to...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement: