High-Throughput and Low-Cost Analysis of Trace Volatile Phthalates in Seafood by Online Coupling of Monolithic Capillary Adsorbent with GC-MS
Related Experiment Video
Updated: Mar 22, 2026

Extraction and Detection of Geosmin and 2-Methylisoborneol in Water and Fish using High-Capacity Sorptive Extraction Probes and GC-MS
Published on: July 3, 2025
Wimonrut Insuan1,2, Phatchara Khawmodjod1,3, Harry J Whitlow1,4
1Department of Chemistry, Kasetsart University , P.O. Box 1011 Chatuchak, Bangkok 10903, Thailand.
Abstract:
A simple, sensitive, and high-throughput method was developed for the determination of six volatile phthalate esters-dimethyl phthalate (DMP), diethyl phthalate (DEP), dibutyl phthalate (DBP), benzylbutyl phthalate (BBP), di(2-ethylhexyl) phthalate (DEHP), and di-n-octyl phthalate (DnOP)-in seafood samples by using monolith adsorbent in a capillary coupled to a gas chromatography-mass spectrometry (GC-MS) system. The freeze-dried samples were subjected to an ultrasonication with hexane, followed by vortex mixing. The liquid extract was quantitatively determined by a direct application to an online silica monolith capillary adsorbent coupled with a gas chromatograph with mass spectrometric detection. Method validation in seafood matrix gave recoveries of 72.8-85.4% and a detection limit of 6.8-10.0 ng g(-1) for bivalve samples. Reusability of the monolith capillary for trapping coextracted matrix was up to six times, allowing high-throughput analysis at the parts per billion level. When compared with the Food and Environment Research Agency (FERA) method, no significant difference in the result was observed, confirming the method was valid and applicable for the routine analysis of phthalates in seafood samples for food and environmental laboratories.
More Related Videos
08:43PTR-ToF-MS Coupled with an Automated Sampling System and Tailored Data Analysis for Food Studies: Bioprocess Monitoring, Screening and Nose-space Analysis
Published on: May 11, 2017
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
High-Performance Liquid Chromatography: Types of Detectors