Methods of analysis for toxic elements in food products. 3. Limit of determination of methods for assuring safety
Related Experiment Video
Updated: Aug 15, 2026

Determination of Inorganic Arsenic in a Wide Range of Food Matrices using Hydride Generation - Atomic Absorption Spectrometry.
Published on: September 1, 2017
1Institute of Nutrition of the USSR Academy of Medical Sciences, Moscow.
Abstract:
To evaluate the suitability of the analytical methods used in determining food safety, a new metrological characteristic "MQS" is suggested. MQS is defined as the absolute minimum quantity in micrograms of a substance that can be determined in a test solution (solubilized test portion). MQS accounts for 2 factors: (a) the necessity for a reliable determination of ML (maximum permitted level, i.e., regulatory tolerance), and (b) the optimum quantity of test portion of a food product to be analyzed, and thus assists in evaluating the suitability of a method to assure food safety. The MQS of 8 toxic elements in any food are As, 3; Cd, 0.5; Cu, 20; Fe, 50; Hg, 0.2; Pb, 4; Sn, 200; Zn, 100 micrograms. To characterize the applicability of any given method, the specific minimum limit of determination, MQSM, must be established for each method. The method in question may be used to control food safety only if MQSM is less than MQS. MQSM values are given for the common polarographic and colorimetric methods for determining these elements.
More Related Videos
06:53Preparation of Food Samples Using Homogenization and Microwave-Assisted Wet Acid Digestion for Multi-Element Determination with ICP-MS
Published on: December 22, 2023
09:51TD-DFT Guided Advanced E-Eye Sensing Technique for On-site Quantification of Fe, Cr, F, and As in the Environmental, Biological, and Food Samples
Published on: September 19, 2025
Related Concept Videos
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
Development of Analytical Methods
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Toxicity Testing in Animals