Methods of analysis for toxic elements in food products. 3. Limit of determination of methods for assuring safety

I M Skurikhin1

  • 1Institute of Nutrition of the USSR Academy of Medical Sciences, Moscow.

Journal - Association of Official Analytical Chemists
|March 1, 1989
PubMed

Related Concept Videos

Difference from Background: Limit of Detection01:05

Difference from Background: Limit of Detection

The limit of detection (LOD) is the smallest amount of analyte that can be distinguished from the background noise. The LOD value corresponds to the concentration at which the analyte signal is three times larger than the standard deviation of the blank signal. Below this value, the analyte signal cannot be differentiated from the background noise. It is calculated by dividing the calibration slope by 3 times the standard deviation of the blank signals.
The LOD indicates the presence or absence...
Effects of EDTA on End-Point Detection Methods01:18

Effects of EDTA on End-Point Detection Methods

Different methods, such as visual observance of metal-ion indicators, spectroscopic techniques, and potentiometric methods, can determine the endpoint of an EDTA titration.
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
Development of Analytical Methods01:21

Development of Analytical Methods

An analytical methodology can be divided into four sequential steps: technique, method, procedure, and protocol. A technique is a scientific principle that rationalizes a specific phenomenon through chemical measurements. Adapting a technique for analyzing a sample of interest is termed a method. The procedure outlines the directions for performing the analysis via an analytical method. The protocol is the detailed guidelines on the procedure, which should be strictly followed to obtain the...
Atomic Absorption Spectroscopy: Lab01:21

Atomic Absorption Spectroscopy: Lab

For AAS measurements, samples must be introduced as clear solutions, often requiring extensive preliminary treatment to dissolve materials like soils, animal tissues, and minerals. Common methods for sample preparation include treatment with hot mineral acids, wet ashing, combustion in closed containers, high-temperature ashing, or fusion with reagents.
 Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Toxicity Testing in Animals01:23

Toxicity Testing in Animals

Toxicity tests in animals are grounded on two main assumptions: first, the effects observed in laboratory animals can be extrapolated to humans, especially when adjusted for body surface area; second, high-dose exposure in animals is essential to identify potential human hazards from lower doses. This is based on the quantal dose-response concept, which faces the challenge of extrapolating results from relatively few test animals to much larger human populations. For example, a 0.01% incidence...