Related Experiment Video
Updated: Mar 22, 2026

Laryngeal Mask Airway LMA Placement in a Neonatal Patient Simulator Using a Non-Inflatable Supraglottic Airway SGA
Published on: July 14, 2023
Maternal sleep-disordered breathing and the risk of delivering small for gestational age infants: a prospective
Sushmita Pamidi1, Isabelle Marc2, Gabrielle Simoneau3
1Respiratory Division and Sleep Laboratory, McGill University Health Centre, Montreal, Quebec, Canada.
Objective:
It is unclear whether objectively measured maternal sleep-disordered breathing (SDB) leads to poor fetal outcomes. In this study, we prospectively assessed whether polysomnography-based diagnosis of SDB in the third trimester is associated with the delivery of small for gestational age (SGA) infants.
Study Design:
Participants were recruited from a multicentre pregnancy cohort study. Eligible participants were evaluated for SDB based on symptoms (snoring and/or witnessed apnoeas assessed using the Pittsburgh Sleep Quality Index questionnaire) and in-home complete polysomnography in the third trimester. SGA was defined as <10th centile using customised birthweight centiles adjusted for maternal parity, prepregnancy body mass index (BMI), ethnicity, gestational age and infant sex.
Results:
Of the 234 pregnant participants who completed a sleep study, 82% were Caucasian, with mean (SD) age of 31 (4.3) years and a prepregnancy BMI of 23 (4) kg/m(2). The delivery of SGA infants occurred in 27 (12%) of the study participants. The symptoms of SDB had poor overall sensitivity and specificity for diagnosing SDB identified by polysomnography. Symptoms of SDB in the third trimester demonstrated a potential association with delivering an SGA infant, however this did not reach statistical significance (OR 2.36 (95% CI 0.85 to 6.54, p=0.10)). However, the odds of delivering an SGA infant were significantly increased with polysomnography-based diagnosis of maternal SDB (using apnoea-hypopnoea index cut-off of 10, OR 2.65 (95% CI 1.15 to 6.10, p=0.02)).
Conclusions:
Objectively measured SDB in the third trimester is significantly associated with the delivery of SGA infants.
Related Concept Videos
Development of the Oral Microbiota
Sleep Apnea
The condition is more prevalent among...
Breathing
Pathophysiology of Diabetes
Type 1 diabetes is characterized by autoimmune-mediated destruction of pancreatic β cells, with environmental factors potentially triggering this process in genetically susceptible individuals. Despite many not having a family history, certain genes increase susceptibility,...
Upper Respiratory Drugs: Antitussives, Expectorants, and Mucolytics
Antitussives include codeine, dextromethorphan (Robitussin), and benzonatate (Tessalon). Codeine and dextromethorphan exert their effects centrally by suppressing the cough reflex center in the medulla. Benzonatate operates peripherally within the respiratory tract by...
Development of Human Microbiota

