Remote reading of coronary CTA exams using a tablet computer: utility for stenosis assessment and identification of coronary anomalies
Related Experiment Video
Updated: Mar 22, 2026

Identifying Coronary Artery Calcification on Non-gated Computed Tomography Scans
Published on: August 28, 2018
Stefan L Zimmerman1,2, Cheng T Lin3, Linda C Chu3
1Department of Radiology and Radiological Sciences, The Johns Hopkins University School of Medicine, Baltimore, MD, USA. stefan.zimmerman@jhmi.edu.
Abstract:
The feasibility of remote reading of coronary CT examinations on tablet computers has not been evaluated. The purpose of this study is to evaluate the accuracy of coronary CT angiography reading using an iPad compared to standard 3D workstations. Fifty coronary CT angiography exams, including a spectrum of coronary artery disease and anatomic variants, were reviewed. Coronary CT angiography exams were interpreted by two readers independently on an iPad application (Siemens Webviewer) and a clinical 3D workstation at sessions 2 weeks apart. Studies were scored per vessel for severity of stenosis on a 0-3 scale (0 none, 1 <50 %, 2 ≥50-69 %, 3 ≥70 %). Coronary anomalies were recorded. A consensus read by two experienced cardiac imagers was used as the reference standard. Level of agreement with the reference for iPad and 3D workstations was compared. Multivariate logistic regression was used to analyze the relationship between agreement and display type and to adjust for inter-reader differences. For both readers, there was no significant difference in agreement with the reference standard for per-vessel stenosis scores using either the 3D workstation or the iPad. In a multivariable logistic regression analysis including reader, workstation, and vessel as co-variates, there was no significant association between workstation type or reader and agreement with the reference standard (p > 0.05). Both readers identified 100 % of coronary anomalies using each technique. Reading of coronary CT angiography examinations on the iPad had no influence on stenosis assessment compared to the standard clinical workstation.
More Related Videos
06:57Author Spotlight: Advancing Cardiovascular Imaging - Introducing the Spatially Weighted Calcium Score for Early Disease Detection
Published on: September 22, 2023
06:16Signal Acquisition, Score Interpretation, and Economics of a Non-Invasive Point-of-Care Test for Coronary Artery Disease
Published on: August 9, 2024
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Acute Coronary Syndrome III: Diagnostic Studies
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...