Identifying Coronary Artery Calcification on Non-gated Computed Tomography Scans
Published on: August 28, 2018
Visual estimation of coronary calcium on computed tomography for attenuation correction
E M Engbers1, J R Timmer1, M Mouden1
1Departments of Cardiology, Isala, Dokter van Heesweg 2, 8025 AB Zwolle, The Netherlands.
Background:
The coronary calcium score (CCS) provides independent diagnostic and prognostic information on top of myocardial perfusion imaging (MPI) in patients suspected for coronary artery disease, but requires an additional computed tomography (CT) scan.
Objective:
We investigated the accuracy and inter-reader reproducibility of visual estimation of the CCS on the CT used for attenuation correction.
Methods:
250 patients undergoing single photon emission computed tomography MPI and Agatston CCS were included. The CCS was also visually estimated on the CT for attenuation correction by two separate readers blinded to the Agatston CCS, and was categorized into a six-point scale (0, 1-10, 11-100, 101-400, 401-1000 and > 1000).
Results:
The median Agatston CCS was 82 [25th-75th percentile: 0-562], with a range from 0 to 7287. Of the visually estimated CCS, 60% (reader 1) and 65% (reader 2) were classified correctly into the 6 categories. 93% (reader 1) and 88% (reader 2) of the visually estimated CCS did not vary by more than one category from the Agatston CCS. The intraclass correlation coefficient for agreement between the Agatston CCS and the visually estimated CCS was 0.95 for reader 1 and 0.94 for reader 2. The intraclass correlation coefficient for inter-reader reproducibility of the visually estimated CCS was 0.96.
Conclusion:
The CCS can be accurately estimated on the CT for attenuation correction, as high agreement is demonstrated with the Agatston CCS and inter-reader reproducibility is excellent. If no traditional Agatston CCS is performed, the degree of atherosclerosis should be assessed by means of estimating CCS on the CT for attenuation correction.
More Related Videos
06:57Author Spotlight: Advancing Cardiovascular Imaging - Introducing the Spatially Weighted Calcium Score for Early Disease Detection
Published on: September 22, 2023
08:02Author Spotlight: Enhanced Quantification of Cardiovascular Calcification Progression for Longitudinal Micro PET/CT Studies in Small Research Animals
Published on: November 15, 2024
Related Concept Videos
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies for Cardiovascular System V: CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Acute Coronary Syndrome III: Diagnostic Studies
Imaging Studies III: Computed Tomography