Standardized Protocol to Analyze Computed Tomography Imaging of Type B Aortic Dissections
Arnoud V Kamman1, Joost A van Herwaarden2, Matteo Orrico3
1Thoracic Aortic Research Center, Policlinico San Donato IRCCS, San Donato Milanese, Italy Department of Vascular Surgery, University Hospital Utrecht, the Netherlands.
A new protocol for measuring type B aortic dissections shows good repeatability for aortic dimensions and volumes. However, accurately measuring entry tears remains challenging, highlighting the need for standardized methodologies in research.
Area of Science:
- Cardiovascular Imaging
- Thoracic Surgery
- Medical Imaging Analysis
Background:
- Type B aortic dissections require precise dimensional measurements for accurate assessment.
- Variability in measurement techniques hinders comparability across studies.
- Standardization is crucial for reliable data in aortic dissection research.
Purpose of the Study:
- To establish a standardized measurement protocol for type B aortic dissections.
- To enhance the comparability of aortic dimensions reported in scientific literature.
- To evaluate the repeatability of aortic measurements using a proposed protocol.
Main Methods:
- A standard protocol was applied to 15 computed tomography (CT) scans of type B aortic dissections.
- Measurements included true/false lumen diameter and volume, and entry tear characteristics.
- Intra- and interobserver repeatability were assessed using Bland-Altman analysis and Lin's concordance correlation coefficient (LCCC).
Main Results:
- The protocol demonstrated acceptable intra- and interobserver repeatability for aortic diameter and lumen volume measurements.
- Lin's concordance correlation coefficient indicated excellent agreement for diameter and volume.
- Repeatable measurement of entry tear size, location, and number proved difficult, with inconsistent results.
Conclusions:
- The proposed protocol is repeatable for aortic diameter and volume measurements in type B aortic dissections.
- Measuring entry tear characteristics presents significant challenges, yielding less favorable results.
- Increased transparency in measurement methodologies is recommended for future aortic dimension studies.
More Related Videos
06:46Quantitative Micro-CT Analysis of Aortopathy in a Mouse Model of β-aminopropionitrile-induced Aortic Aneurysm and Dissection
Published on: July 16, 2018
07:12Author Spotlight: Using Point-of-Care Ultrasound for Comprehensive Evaluation of the Abdominal Aorta
Published on: September 8, 2023
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Aneurysm II: Clinical Manifestations and Diagnostic Studies
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Aortic Regurgitation II: Clinical Features and Diagnostic Tests