Impact of contamination with long-lived radionuclides on PET kinetics modelling in multitracer studies
Lars Jødal1, Søren B Hansen, Svend B Jensen
1aDepartment of Veterinary Disease Biology, University of Copenhagen, Copenhagen bDepartment of Nuclear Medicine & PET Center, Aarhus University Hospital, Aarhus cDepartment of Nuclear Medicine, Aalborg University Hospital dDepartment of Chemistry and Biochemistry, Aalborg University, Aalborg, Denmark.
Introduction:
An important issue in multitracer studies is the separation of signals from the different radiotracers. This is especially the case when an early tracer has a long physical half-life and kinetic modelling has to be performed, because the early tracer can confer a long-lived contaminating background not only to images but also to a measured input function derived from blood samples. In this study, we examined data from a sequential multitracer infection study involving In (t1/2=2.8 days), investigating the influence on gamma counting of blood samples and on the kinetic modelling of subsequent PET tracers. Blood sample counts were corrected by recounting the samples a few days later. A more optimal choice of energy window was also explored. The effect of correction versus noncorrection was investigated using a two-tissue kinetic model with irreversible uptake (K1, k2, k3).
Results:
K1 was least affected and k3 was most affected by the contamination, corresponding to the effect being relatively larger on the late part of the blood input function. A narrower energy window reduced the problem, but this will not be possible for all types of contaminating background.
Conclusion:
Gamma counting of blood samples can lead to a contaminating background not observed in PET imaging and this background can affect kinetic modelling. If the contaminating tracer has a much longer half-life than the foreground tracer, then the problem can be solved by late recounting of the samples.
More Related Videos
06:31Quantitative [18F]-Naf-PET-MRI Analysis for the Evaluation of Dynamic Bone Turnover in a Patient with Facetogenic Low Back Pain
Published on: August 8, 2019
10:21Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function
Published on: August 8, 2019
Related Concept Videos
Radioactive Decay and Radiometric Dating
Isotopes and Radioisotopes
An isotope containing...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET