Shrinkage of Dental Composite in Simulated Cavity Measured with Digital Image Correlation
Published on: July 21, 2014
Depth and distribution of the cure in a resin-based composite cured in a simulated Class II cavity
Purpose:
To examine the effect that a stainless steel (SS) matrix band has on the depth and distribution of cure of a resin-based composite (RBC) in a simulated Class II cavity.
Methods:
RBC was cured for 20 seconds in a simulated Class II cavity with and without a SS matrix band, and after 24 hours the specimens were scraped back and ground to expose a vertical central plane where Knoop micro-hardness (KHN) mapping was conducted from 0.05-1.5 mm from the band and in 0.5 mm intervals from the top of the specimens. The effect of different angles of the light guide on the distribution of hardness was also examined.
Results:
KHN values near the SS matrix band were significantly lower (P < 0.05) than within the bulk of the specimen and were lower than those found without the matrix band. Angles of incidence for the curing light-guide produced changes in the distribution of KHN within the specimens, but particularly near the matrix band, and with a 35° angle of incidence, the depth of cure was significantly different from that of normal incidence of the light.
More Related Videos
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
05:30Roughness Impact of Piezoelectric Dental Scaler on Two Distinct Flowable Composite Filling Materials
Published on: January 10, 2025
Related Concept Videos
Accelerated Curing of Concrete
Curing Methods
Curing of Concrete
Porosity in Cement Paste
The balance of water to cement in the mix is...