Related Experiment Video
Updated: Mar 22, 2026

11:21
Cooling an Optically Trapped Ultracold Fermi Gas by Periodical Driving
Published on: March 30, 2017
8.0K
Erratum: Multimode Kapitza-Dirac Interferometry with Trapped Cold Atoms [Phys. Rev. Lett. 113, 023003 (2014)]
Physical Review Letters
|April 23, 2016
Summary
This study corrects a previously published article's Digital Object Identifier (DOI). The correction ensures accurate citation and retrieval of the scientific research for better accessibility.
Area of Science:
- Bibliometrics
- Scientific Publishing
Background:
- Accurate citation is crucial for scientific integrity and reproducibility.
- Digital Object Identifiers (DOIs) are essential for uniquely identifying and linking to scholarly articles.
Purpose of the Study:
- To correct an erroneous Digital Object Identifier (DOI) associated with a published article.
- To ensure the accurate referencing and retrieval of scientific literature.
Main Methods:
- A review of the article's metadata was conducted.
- The incorrect DOI was identified and cross-referenced with the correct identifier.
Main Results:
- The Digital Object Identifier (DOI) for the article published in Physical Review Letters has been corrected.
- The correction ensures that readers can accurately access the intended research paper.
Conclusions:
- This correction enhances the reliability of scientific records.
- Accurate DOIs are fundamental for maintaining the integrity of the scientific communication process.
Related Concept Videos
Atomic Force Microscopy
4.7K
Atomic force microscopy (AFM) is a type of scanning probe microscopy that can analyze topographic details of various specimens like ceramics, glass, polymers, and biological samples. AFM offers over 1000 times more resolution than the optical imaging system. Images generated from AFM are three-dimensional surface profiles, offering an advantage over the flat, two-dimensional images from other imaging techniques.
The AFM Probe
The probe is regarded as the heart of any AFM setup and comprises the...
The AFM Probe
The probe is regarded as the heart of any AFM setup and comprises the...
4.7K
Mass Analyzers: Common Types
1.8K
The quadrupole mass analyzer consists of four cylindrical metal rods arranged in a diamond carrying a DC voltage and a radio-frequency AC voltage. The motion of ions through the quadrupole depends on the field strength, causing only ions of a certain m/z to resonate successfully and strike the detector at a given field strength. Though the transmission rate for these analyzers is high, the exact elemental composition of the sample is not determined because of low resolution; however, they are...
1.8K
Atomic Absorption Spectroscopy: Interference
2.3K
Interference leads to systematic error in atomic absorption (AA) measurements by enhancing or diminishing the analytical signal or the background. These interferences can be grouped into three main categories: spectral interference, chemical interference, and physical interference.
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
2.3K
Atomic Emission Spectroscopy: Interference
735
In atomic emission spectroscopy (AES), high-temperature atomizers excite a broad range of elements and molecules that generate complex emissions from sources such as oxides, hydroxides, and flame combustion products in the flame or plasma. Several strategies can be employed to minimize spectral interferences caused by overlapping emission lines or bands. These include increasing instrument resolution, choosing alternative emission lines, optimally placing the detector in low-background regions,...
735
Atomic Absorption Spectroscopy: Instrumentation
2.0K
An atomic absorption spectrophotometer (AAS) comprises several components: a radiation source, an atomizer, a monochromator, and a detector. The radiation source can be a hollow-cathode lamp (HCL) or an electrodeless-discharge lamp (EDL), both of which provide a narrow emission line of the required wavelength. However, some instruments use continuum sources and high-resolution monochromators to achieve a narrow range of radiation.
The atomizer used in AAS can be either a flame atomizer or an...
The atomizer used in AAS can be either a flame atomizer or an...
2.0K
Atomic Nuclei: Larmor Precession Frequency
3.5K
The earth's gravitational field produces a 'twisting force' perpendicular to the angular momentum of a spinning mass (such as a spinning top) that causes the mass to 'wobble' around the gravitational field axis in a phenomenon called precession. Similarly, the magnetic moment (μ) of a spinning nucleus precesses due to an external magnetic field directed along the z-axis. The precession of the magnetic moment vector about the magnetic field is called Larmor precession,...
3.5K

