Development and evaluation of a secondary reference panel for BCR-ABL1 quantification on the International Scale
N C P Cross1,2, H E White1,2, T Ernst3
1Wessex Regional Genetics Laboratory, Salisbury NHS Foundation Trust, Salisbury, UK.
Leukemia
|April 26, 2016
Summary
A new cell-based reference panel improves BCR-ABL1 testing accuracy for chronic myeloid leukemia patients. This tool aids global laboratories in achieving reliable molecular monitoring and treatment decisions.
Area of Science:
- Hematology
- Molecular Diagnostics
- Oncology
Background:
- Accurate BCR-ABL1 molecular monitoring standardized to the International Scale (IS) is crucial for managing chronic myeloid leukemia (CML), particularly for treatment cessation decisions.
- Current IS calibration relies on time-consuming sample exchange with reference labs, and access to the World Health Organization (WHO) BCR-ABL1 reference panel is limited.
Purpose of the Study:
- To develop the first cell-based secondary reference panel for BCR-ABL1 testing, traceable to the WHO panel.
- To provide a more accessible and reliable tool for International Scale (IS) calibration and assay validation worldwide.
- To assess the performance of BCR-ABL1 assays using the developed secondary reference panel.
Main Methods:
- Development of a cell-based secondary reference panel with levels from MR(1) to MR(4.5).
- Calibration of the panel to IS using digital PCR with ABL1, BCR, and GUSB as reference genes.
- Evaluation of the panel by 44 laboratories globally, assessing assay optimization, IS accuracy, precision, and sensitivity.
Main Results:
- >40% of BCR-ABL1 assays exhibited inadequate optimization (e.g., poor linearity, suboptimal PCR efficiency).
- When using optimized inputs, >60% of assays showed satisfactory IS accuracy, precision, and/or MR(4.5) sensitivity.
- 58% of labs obtained IS conversion factors from the secondary panel concordant with their existing values; assay configuration did not significantly alter %BCR-ABL1 results.
Conclusions:
- The developed secondary reference panel is traceable to the WHO panel and replicates its performance.
- Significant assay optimization issues were identified, highlighting the need for improved IS calibration mechanisms.
- The panel demonstrates potential for enhancing the accuracy and reliability of BCR-ABL1 testing in global molecular diagnostics.