Related Experiment Video
Updated: Mar 22, 2026

Standardized Hemorrhagic Shock Induction Guided by Cerebral Oximetry and Extended Hemodynamic Monitoring in Pigs
Published on: May 21, 2019
Changes in the central and peripheral circulatory system in response to the cold: own studies using impedance
Elżbieta Łastowiecka-Moras1, Eliza Kozyra-Pydyś2
1a Central Institute for Labour Protection - National Research Institute (CIOP-PIB) , Poland.
Abstract:
The aim of the study was to determine the cardiovascular response to continuous (4 °C for 60 min) and intermittent (10 min at 4 °C and 10 min at room temperature alternately) exposure to the cold in 30 healthy young men. The subjects were equipped with a set of identical clothing (insulation 2.1 clo) and during the stay in the chamber and outside performed the same activities, i.e., walking on a treadmill at a speed of 0.5 km/h. The tests included assessing the central circulatory system using the Holter system and assessing the peripheral circulatory system using impedance plethysmography and Doppler ultrasound. The analysis of the parameters that describe the central and peripheral circulation poses a difficulty in determining which variant of exposure constitutes a greater load on the circulatory system. It should be noted that even the conditions used in the study may cause adverse effects in the cardiovascular system.
More Related Videos
08:25Impedance Pneumography for Minimally Invasive Measurement of Heart Rate in Late Stage Invertebrates
Published on: April 4, 2020
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps: