Related Experiment Video
Updated: Mar 22, 2026

Assessing Cerebral Autoregulation via Oscillatory Lower Body Negative Pressure and Projection Pursuit Regression
Published on: December 10, 2014
Central blood pressure assessment using oscillometry is feasible for everyday clinical practice
A Reshetnik1, C Gohlisch1, W Zidek1
1Department of Nephrology and Transplantation, Charité University Berlin, Campus Benjamin Franklin, Berlin, Germany.
Abstract:
The benefit of the central systolic blood pressure (cSBP) has already been recognized, but its general measurement in the everyday routine is still limited mainly because available established non-invasive assessment devices are not suitable for everyday use. In this study, we investigated the performance of an oscillometric device Tel-O-GRAPH for cSBP assessment in terms of suitability for everyday clinical use. One hundred and three patients were prospectively included. cSBP was computed by Tel-O-GRAPH compared with Sphygmocor using applanation tonometry. There was a good agreement between Tel-O-GRAPH and Sphygmocor for cSBP (mean difference±s.d.: -0.3±6.7 mm Hg; Pearson's R=0.95; P<0.0001). Recorded cSBP values in the supine vs seated position and for the experienced vs non-experienced user did not significantly differ (mean cSBPsupine 122.1±13.9 mm Hg vs cSBPseated 120.7±15.7 mmHg; cSBPnon-experienced 120.6±20.5 mm Hg and cSBPexperienced 119.2±19.9 mm Hg). The mean difference of cSBP between supine and seated positions was 1.5±6.8 and -1.4±5.0 mm Hg between experienced and non-experienced users. This study showed good accuracy in assessing cSBP with an oscillometric BP measurement device Tel-O-GRAPH compared with a Sphygmocor. Furthermore, the calculation of cSBP by Tel-O-GRAPH appears to be easy and can be done during the routine brachial BP measurement. Computed cSBP values seem to remain reliable independently of the patient body position and experience of the operator. Consequently, the easiness of utilization and reliability of the device may open the opportunity for its extended use in everyday clinical practice, as well as reliable alternative for clinical studies, making complex applanation tonometry dispensable.
Related Concept Videos
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of blood pressure in brachial artery(two-step method)
Measurement of Blood Pressure
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement

