Related Experiment Video
Updated: Mar 22, 2026

Determining Viral Disinfection Efficacy of Hot Water Laundering
Published on: June 21, 2022
Single-use technology for solvent/detergent virus inactivation of industrial plasma products
Yao-Ting Hsieh1, Lori Mullin2, Patricia Greenhalgh2
1Graduate Institute of Biomedical Materials and Tissue Engineering, College of Biomedical Engineering, Taipei Medical University, Taipei, Taiwan;
Background:
Virus inactivation of plasma products is conducted using stainless-steel vessels. Single-use technology can offer significant benefits over stainless such as operational flexibility, reduced capital infrastructure costs, and increased efficiency by minimizing the time and validation requirements associated with hardware cleaning. This study qualifies a single-use bag system for solvent/detergent (S/D) virus inactivation.
Study Design And Methods:
Human plasma and immunoglobulin test materials were S/D-treated in Mobius single-use bags using 1% tri-n-butyl phosphate (TnBP) with 1% Triton X-100 or 1% Tween 80 at 31°C for 4 to 6 hours to evaluate the impact on protein quality. Volatile and nonvolatile organic leachables from low-density polyethylene film (Pureflex film) used in 1-L-scale studies after exposure to S/D in phosphate-buffered saline were identified compared to controls in glass containers. Virus inactivation studies were performed with xenotropic murine leukemia virus (XMuLV) and bovine viral diarrhea virus (BVDV) to determine the kinetics of virus inactivation, measured using infectivity assays.
Results:
S/D treatment in Mobius bags did not impact the protein content and profile of plasma and immunoglobulin, including proteolytic enzymes and thrombin generation. Cumulative leachable levels after exposure to S/D were 1.5 and 1.85 ppm when using 0.3% TnBP combined with 1% Tween 80 or 1% Triton X-100, respectively. Efficient inactivation of both XMuLV and BVDV was observed, with differences in the rate of inactivation dependent on both virus and S/D mixture.
Conclusion:
Effective S/D virus inactivation in single-use container technology is achievable. It does not alter plasma proteins and induces minimal release of leachables.
Related Concept Videos
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Detergent Purification of Membrane Proteins
Chemical Agents for Microbial Control
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...

