Occupational health risks associated with the use of germicides in health care
David J Weber1, Stephanie A Consoli2, William A Rutala1
1Department of Hospital Epidemiology, University of North Carolina Health Care, Chapel Hill, NC; Department of Occupational Health, University of North Carolina Health Care, Chapel Hill, NC; Division of Infectious Diseases, University of North Carolina School of Medicine, Chapel Hill, NC.
Abstract:
Environmental surfaces have been clearly linked to transmission of key pathogens in health care facilities, including methicillin-resistant Staphylococcus aureus, vancomycin-resistant Enterococcus, Clostridium difficile, norovirus, and multidrug-resistant gram-negative bacilli. For this reason, routine disinfection of environmental surfaces in patient rooms is recommended. In addition, decontamination of shared medical devices between use by different patients is also recommended. Environmental surfaces and noncritical shared medical devices are decontaminated by low-level disinfectants, most commonly phenolics, quaternary ammonium compounds, improved hydrogen peroxides, and hypochlorites. Concern has been raised that the use of germicides by health care personnel may increase the risk of these persons for developing respiratory illnesses (principally asthma) and contact dermatitis. Our data demonstrate that dermatitis and respiratory symptoms (eg, asthma) as a result of chemical exposures, including low-level disinfectants, are exceedingly rare. Unprotected exposures to high-level disinfectants may cause dermatitis and respiratory symptoms. Engineering controls (eg, closed containers, adequate ventilation) and the use of personal protective equipment (eg, gloves) should be used to minimize exposure to high-level disinfectants. The scientific evidence does not support that the use of low-level disinfectants by health care personnel is an important risk for the development of asthma or contact dermatitis.
Insights
Healthcare workers face low risk of respiratory illness or dermatitis from low-level disinfectants. High-level disinfectants require protective measures to prevent adverse health effects.
Area of Science:
- Infection Control
- Occupational Health
- Environmental Hygiene
Background:
- Environmental surfaces are a known route for pathogen transmission in healthcare settings.
- Routine disinfection of surfaces and medical devices is crucial for patient safety.
- Common low-level disinfectants include phenolics, quaternary ammonium compounds, hydrogen peroxides, and hypochlorites.
Purpose of the Study:
- To evaluate the risk of respiratory illnesses and contact dermatitis in healthcare personnel due to disinfectant exposure.
- To assess the safety profile of low-level disinfectants commonly used in healthcare environments.
Main Methods:
- Review of scientific evidence regarding disinfectant exposure and health outcomes in healthcare workers.
- Analysis of reported cases of respiratory symptoms and dermatitis linked to chemical exposures.
Main Results:
- Adverse health effects such as dermatitis and respiratory symptoms (e.g., asthma) from low-level disinfectant exposure are rare.
- High-level disinfectants, when used without protection, can cause respiratory and skin issues.
- Engineering controls and personal protective equipment are recommended for high-level disinfectant use.
Conclusions:
- The use of low-level disinfectants by healthcare personnel is not a significant risk factor for developing asthma or contact dermatitis.
- Implementing safety measures is essential when handling high-level disinfectants to mitigate potential health risks.
Related Concept Videos
Hand hygiene
Hand washing...
Standard Precaution
Hand hygiene is the most crucial means to prevent the transmission of disease. Employers are legally required to provide their workers with personal protective equipment (PPE) to minimize exposure or contact with...
Healthcare Associated Infections II: Preventive Measures
The best practices for preventing healthcare-associated infections include hand hygiene, patient risk...
Chemical Agents for Microbial Control
Healthcare Associated Infections I: Iatrogenic, Exogenic and Endogenic
HAIs significantly increase the cost of health care. Extended stays in healthcare institutions, increased disability, increased costs of medications, including specialized antibiotics, and prolonged recovery times add to the patient's expenses and the healthcare institution and funding bodies.
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...