Validity and repeatability of three in-shoe pressure measurement systems
Carina Price1, Daniel Parker1, Christopher Nester1
1Centre for Health Sciences Research, University of Salford, United Kingdom.
Abstract:
In-shoe pressure measurement devices are used in research and clinic to quantify plantar foot pressures. Various devices are available, differing in size, sensor number and type; therefore accuracy and repeatability. Three devices (Medilogic, Tekscan and Pedar) were examined in a 2 day×3 trial design, quantifying insole response to regional and whole insole loading. The whole insole protocol applied an even pressure (50-600kPa) to the insole surface for 0-30s in the Novel TruBlue™ device. The regional protocol utilised cylinders with contact surfaces of 3.14 and 15.9cm(2) to apply pressures of 50 and 200kPa. The validity (% difference and Root Mean Square Error: RMSE) and repeatability (Intra-Class Correlation Coefficient: ICC) of the applied pressures (whole insole) and contact area (regional) were outcome variables. Validity of the Pedar system was highest (RMSE 2.6kPa; difference 3.9%), with the Medilogic (RMSE 27.0kPa; difference 13.4%) and Tekscan (RMSE 27.0kPa; difference 5.9%) systems displaying reduced validity. The average and peak pressures demonstrated high between-day repeatability for all three systems and each insole size (ICC≥0.859). The regional contact area % difference ranged from -97 to +249%, but the ICC demonstrated medium to high between-day repeatability (ICC≥0.797). Due to the varying responses of the systems, the choice of an appropriate pressure measurement device must be based on the loading characteristics and the outcome variables sought. Medilogic and Tekscan were most effective between 200 and 300kPa; Pedar performed well across all pressures. Contact area was less precise, but relatively repeatable for all systems.
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(two-step method)
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Measurement of Blood Pressure
Measurement of Fluid Pressure
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
Assessing Blood pressure in the Leg
Preparation: