Related Experiment Video
Updated: Mar 21, 2026

Tilt Testing with Combined Lower Body Negative Pressure: a "Gold Standard" for Measuring Orthostatic Tolerance
Published on: March 21, 2013
Enhancing the accuracy of the Fowler method for monitoring non-constant work functions
1AG Experimentelle Plasmaphysik, Universität Augsburg, 86135 Augsburg, Germany.
Abstract:
The Fowler method is a prominent non-invasive technique to determine the absolute work function of a surface based on the photoelectric effect. The evaluation procedure relies on the correlation of the photocurrent with the incident photon energy hν which is mainly dependent on the surface work function χ. Applying Fowler's theory of the photocurrent, the measurements can be fitted by the theoretical curve near the threshold hν⪆χ yielding the work function χ and a parameter A. The straightforward experimental implementation of the Fowler method is to use several particular photon energies, e.g. via interference filters. However, with a realization like that the restriction hν ≈ χ can easily be violated, especially when the work function of the material is decreasing during the measurements as, for instance, with coating or adsorption processes. This can lead to an overestimation of the evaluated work function value of typically some 0.1 eV, reaching up to more than 0.5 eV in an unfavorable case. A detailed analysis of the Fowler theory now reveals the background of that effect and shows that the fit-parameter A can be used to assess the accuracy of the determined value of χ conveniently during the measurements. Moreover, a scheme is introduced to quantify a potential overestimation and to perform a correction to χ to a certain extent. The issues are demonstrated exemplarily at the monitoring of the work function reduction of a stainless steel sample surface due to caesiation.
More Related Videos
Related Concept Videos
Work Done During Volume Change
Consider a gas confined to a cylinder fitted with a movable piston at one end. If the gas expands from volume V1 to volume V2, it exerts a force on the piston, such that the piston moves by a distance dr.
The work done by the gas on the piston can be expressed as
Quantifying Work
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
One-Compartment Open Model: Wagner-Nelson and Loo Riegelman Method for ka Estimation
On...
Work and Energy for Variable Forces
Substitution Rule Applied to Indefinite Integrals

