Gadolinium-free MR in coarctation-can contrast-enhanced MR angiography be replaced?
Peter I Kalmar1, Martin Koestenberger2, Robert Marterer3
1Department of Radiology, Division of Pediatric Radiology, Medical University of Graz, LKH-Univ. Klinikum Graz, Austria; Department of Radiology, Division of Vascular and Interventional Radiology, Medical University of Graz, LKH-Univ. Klinikum Graz, Austria.
Insights
Cine MRI and gadolinium-free MRA offer equivalent vessel size monitoring to contrast-enhanced MRA in coarctation of the aorta patients. These noninvasive techniques provide comparable measurements and signal-to-noise ratios, with only voxel size differing significantly.
Area of Science:
- Cardiovascular Imaging
- Medical Physics
- Radiology
Background:
- Coarctation of the aorta (CoA) requires regular monitoring of vessel dimensions.
- Contrast-enhanced magnetic resonance angiography (ce-MRA) is a standard but invasive imaging technique.
- Noncontrast magnetic resonance techniques offer potential for less invasive assessment.
Purpose of the Study:
- To compare vessel measurements, signal-to-noise ratio (SNR), and voxel size between contrast-enhanced and noncontrast MRI techniques in CoA patients.
- To evaluate the efficacy of cine MRI and gadolinium-free MRA against ce-MRA for assessing aortic dimensions.
Main Methods:
- A comparative study involving 39 patients diagnosed with coarctation of the aorta.
- Vessel size, SNR, and voxel size were analyzed across three MRI sequences: cine MRI, gadolinium-free MRA (Gd-free MRA), and ce-MRA.
Main Results:
- No statistically significant differences were observed in vessel size measurements or SNR between the evaluated MRI techniques.
- A significant difference (P<.001) was found in voxel size across the imaging modalities.
- Voxel size varied, but this did not impact the accuracy of vessel dimension or SNR assessment.
Conclusions:
- Cine MRI and Gd-free MRA provide equivalent vessel size monitoring compared to ce-MRA in patients with coarctation of the aorta.
- These noncontrast techniques are less invasive alternatives for routine monitoring of vessel dimensions in CoA.
- The findings support the use of noninvasive MRI methods for improved patient management in coarctation of the aorta.
Objective:
To determine the difference in vessel measurements, signal-to-noise ratio (SNR), and voxel size between contrast-enhanced and noncontrast magnetic resonance techniques in patients with coarctation of the aorta (CoA).
Materials And Methods:
In 39 patients, vessel size, SNR, and voxel size were compared in cine magnetic resonance imaging (MRI), gadolinium-free magnetic resonance angiography (Gd-free MRA), and contrast-enhanced MRA (ce-MRA).
Results:
There was no significant difference in measurement and SNR, but there was a significant difference in voxel size (P<.001).
Conclusions:
Our results show that, in CoA patients, monitoring of vessel size using cine MRI and Gd-free MRA is equivalent to ce-MRA while being less invasive.
Related Concept Videos
Imaging Studies for Cardiovascular System IV: CMRI
Magnetic Resonance Imaging
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Imaging Studies for Cardiovascular System V: CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...