Which is More Accurate in Measuring the Blood Pressure? A Digital or an Aneroid Sphygmomanometer
Bhaskar Shahbabu1, Aparajita Dasgupta2, Kaushik Sarkar1
1Junior Resident, Department of PSM, AIIH&PH , Kolkata, West Bengal, India .
Introduction:
Hypertension is one of the major public health problem affecting the whole world so its accurate measurement is of utmost importance for its early diagnosis and management. Concerns related to the potential ill effects of mercury on health and environment, has led to the widespread use of non-mercury sphygmomanometers.
Aim:
A study was conducted to compare the accuracy of readings of aneroid and digital sphygmomanometers in reference to mercury sphygmomanometers and determine the hypertensive classification agreement between the mercury and non-mercury devices.
Materials And Methods:
The study was conducted in an OPD of a health centre in a rural community of West Bengal which is the rural field practice area of our institute. An aneroid and a digital sphygmomanometer were compared to a properly calibrated mercury sphygmomanometer. All the subjects above the age of 25 years, in two days per week, selected randomly from five working days per week in a period of one month were selected. Two blood pressure readings of each of 218 study subjects was recorded with each pretested sphygmomanometer. Paired t-test, Kappa coefficients, sensitivity and specificity tests were done. Receiver Operating Characteristics curve analysis was done and Youden index was estimated to detect the optimal cut off point for the diagnosis of hypertension by non-mercury sphygmomanometers.
Results:
Data analysis of 218 study subjects showed the mean difference of the mercury reading and the test device was much less for aneroid than that of the digital device for both systolic and diastolic blood pressure. More than 89% of aneroid readings and less than 44% of the readings by digital device had absolute difference of 5mm Hg. when compared with the mercury readings for both systolic and diastolic blood pressure. Sensitivity and specificity of aneroid device was higher (86.7% and 98.7%) than digital device (80% and 67.7%). Receiver Operating Characteristic curve had larger area under the curve for aneroid device than digital device for both SBP and DBP.
Conclusion:
The aneroid device had better accuracy than the digital device as compared to mercury sphygmomanometer and should be used for proper and better management.
More Related Videos
05:51Measuring the Carotid to Femoral Pulse Wave Velocity Cf-PWV to Evaluate Arterial Stiffness
Published on: May 3, 2018
05:51Assessing the Accuracy of Fitness Smartwatch Data for Cardiovascular and Physical Activity Monitoring: A Validation Study in Digital Health
Published on: February 21, 2025
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Measurement of Blood Pressure
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.