Fluoro-substituted tetraphenyl-phenyl grafted polysiloxanes as highly selective stationary phases for gas
Xue Han1, Xinxin He1, Huan Wang1
1School of Chemistry and Chemical Engineering, Shandong University, 27 Shanda South Road, 250100, China.
Abstract:
In this work, two new types of polycyclic aromatic grafted polysiloxanes, namely, 3,4-bis(4-fluoro phenyl)-2,5-diphenyl polysiloxane (FPP) and 3,4-bis(3,4,5-trifluoro phenyl)-2,5-diphenyl polysiloxane (TFPP), were synthesized and statically coated onto capillary columns as stationary phases for gas chromatography (GC). Based on their McReynolds constants, both columns exhibited moderate polarity. The efficiencies of the FPP and TFPP columns were 3316 (k=3.96, naphthalene; 0.25mm inner diameter) and 3768 (k=4.14, naphthalene; 0.25mm inner diameter) plates/m, respectively. The thermostability of the polymers was tested by thermogravimetric analysis (TGA), and results revealed that both TFPP and FPP began to decompose slightly at 380°C. Separation of polyethylene pyrolysis products showed that the upper working temperature of the two columns can reach up to 360°C. Relying on their unique polarizable characteristics in combination with other types of interactions, such as H-bond acceptor, dipole-dipole, and dispersive interactions, the newly synthesized polarizable stationary phases offered unique selectivity for aromatic isomers and substituted benzenes. A slight separation difference between TPP and TFPP was observed. TFPP also exerted excellent selectivity for polycyclic aromatic hydrocarbons, fatty acid esters, and fatty alcohols. Overall, FPP and TFPP demonstrated considerable potential for further applications because of their unique structures and outstanding separation performance.
Related Concept Videos
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
Gas Chromatography: Types of Detectors-II