Related Experiment Video
Updated: Mar 21, 2026

Comprehensive Endovascular and Open Surgical Management of Cerebral Arteriovenous Malformations
Published on: October 20, 2017
Large Residual Volume, Not Low Packing Density, Is the Most Influential Risk Factor for Recanalization after Coil
Akiyo Sadato1, Motoharu Hayakawa1, Kazuhide Adachi1
1Department of Neurosurgery, Fujita Health University, Toyoake City, Aichi, Japan.
Background:
Tight coil packing with density of at least 20%-25% is known to be important for preventing recanalization after embolization of cerebral aneurysms. However, large aneurysms sometimes recanalize regardless of the packing density, suggesting that the absolute residual volume which is determined by aneurysm volume and packing density may be more important risk factor for recanalization. To validate this hypothesis, we analyzed the factors affecting the outcomes of treated aneurysms at our institute.
Methods And Findings:
We included 355 small and large aneurysms. The following six factors were obtained from every case: aneurysm volume (mL), neck size (mm), packing density (%), residual volume (mL), rupture status at presentation, and stent assistance (with or without stent). The data were then subjected to multivariate logistic regression analysis to identify significant risk factors for recanalization. Recanalization occurred in 61 aneurysms (17.2%). Significant predictors for recanalization were aneurysm volume (odds ratio, 15.3; P < 0.001) and residual volume (odds ratio, 30.9; P < 0.001), but not packing density (odds ratio, 0.98; P = 0.341). These results showed that for each 0.1-mL increase in aneurysm volume and residual volume, the risk of recanalization increased by 1.3 times and 1.4 times, respectively.
Conclusions:
The most influential risk factor for recanalization after coil embolization was residual volume, not packing density. The larger the aneurysm volume, the greater the packing density has to be to minimize the residual volume and risk of recanalization. Since tight coil packing has already been aimed, further innovation of coil property or embolization technique may be needed. Otherwise, different treatment modality such as flow diverter or parent artery occlusion may have to be considered.
Related Concept Videos
Aneurysm III: Interprofessional Care
Aneurysm IV: Nursing Management
Aneurysm II: Clinical Manifestations and Diagnostic Studies