Related Experiment Video
Updated: Mar 21, 2026

Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
Published on: December 11, 2017
Long-Term Survival and Freedom From Reoperation After Placement of a Pulmonary Xenograft Valved Conduit
George M Alfieris1, Michael F Swartz1, Juan Lehoux1
1Department of Surgery, University of Rochester Medical Center, Rochester, New York.
Background:
The optimal choice for pulmonary valve replacement (PVR) remains controversial. This study hypothesized that xenografts used for PVR would result in prolonged long-term survival and freedom from reoperation.
Methods:
Children and adults with congenital heart disease requiring PVR using a xenograft from 1980 to 1985 were reviewed. In all cases, the xenograft valve was either sewn or manufactured into a Dacron conduit, and the conduit was sewn to the pulmonary artery bifurcation. Clinical data were analyzed, and survival and freedom from reoperation were determined using Kaplan-Meier analysis.
Results:
Twenty-four patients received a xenograft for PVR at 14.6 ± 5.6 years. Conduit size ranged from 21 to 27 mm. Most patients received a Carpentier-Edwards valved conduit (n = 17), followed by a Hancock valved conduit (n = 5) and an Ionescu-Shiley valve sewn into a Dacron graft (n = 2). No perioperative deaths occurred. Reoperation was required mainly for pulmonary stenosis (72.7%), followed by pulmonary insufficiency (18.2%), or both stenosis and insufficiency (9%). Freedom from reoperation was 90%, 56%, 43%, and 14% at 10, 20, 25, and 30 years, respectively. At most recent follow-up the was only death, which was related to severe biventricular failure 25 years after conduit implant.
Conclusions:
PVR using a xenograft valved conduit results in prolonged freedom from reoperation and excellent long-term survival. These data, which provide long-term follow-up information on xenograft valves after PVR.