Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Integrated gas chromatography for ultrafast analysis of volatile organic compounds in air
Yanggang Zhang1, Dapeng Wu2, Xiaohui Yan2
1Key Laboratory of Separation Science for Analytical Chemistry of CAS, Department of Instrumentation & Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, 457 Zhongshan Road, Dalian 116023, PR China; University of Chinese Academy of Sciences, Beijing 100039, PR China.
Abstract:
An integrated instrumentation of a cryogenic microtrap-thermal desorption-low thermal mass (LTM) fast gas chromatographic (GC) system had been designed and evaluated for the ultrafast enrichment and separation of trace amounts of highly volatile organic compounds (VOCs) in air. The LTM fast GC column was wrapped uniformly on outer surface of a thin metal heating cylinder of 65mm O.D. and 0.5mm in thickness. Both of microtrap and LTM column could be rapidly cooled by liquid CO2 down to -35°C, and heated by resistive heating. A 10m×100µm i.d. micro-bore capillary column was used in the LTM GC column module to provide a high separation speed. Key operational parameters, including adsorbent mass, trapping temperature, thermal desorption temperature and injection time were optimized. Under the optimized condition, the 39 species of TO-14 VOCs were well resolved and quantified in less than 3min. The detection limits were in the range of 8 ppt-0.22 ppb at sampling volume of 50mL and trapping temperature of -10°C. The average peak width was 0.9s, and the peak capacity of ~150 (at unit resolution) was obtained. The applicability of the setup was evaluated by analyzing three real environmental samples, where some typical VOCs at sub ppb level were detected.
More Related Videos
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
05:31Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...