Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Calibration Curves: Linear Least Squares01:20

Calibration Curves: Linear Least Squares

5.1K
A calibration curve is a plot of the instrument's response against a series of known concentrations of a substance. This curve is used to set the instrument response levels, using the substance and its concentrations as standards. Alternatively, or additionally, an equation is fitted to the calibration curve plot and subsequently used to calculate the unknown concentrations of other samples reliably.
For data that follow a straight line, the standard method for fitting is the linear...
5.1K
Estimating Population Mean with Unknown Standard Deviation01:22

Estimating Population Mean with Unknown Standard Deviation

9.0K
In practice, we rarely know the population standard deviation. In the past, when the sample size was large, this did not present a problem to statisticians. They used the sample standard deviation s as an estimate for σ and proceeded as before to calculate a confidence interval with close enough results. However, statisticians ran into problems when the sample size was small. A small sample size caused inaccuracies in the confidence interval.
William S. Gosset (1876–1937) of the...
9.0K
Residuals and Least-Squares Property01:11

Residuals and Least-Squares Property

9.8K
The vertical distance between the actual value of y and the estimated value of y. In other words, it measures the vertical distance between the actual data point and the predicted point on the line
If the observed data point lies above the line, the residual is positive, and the line underestimates the actual data value for y. If the observed data point lies below the line, the residual is negative, and the line overestimates the actual data value for y.
The process of fitting the best-fit...
9.8K
One-Compartment Open Model: Wagner-Nelson and Loo Riegelman Method for ka Estimation01:24

One-Compartment Open Model: Wagner-Nelson and Loo Riegelman Method for ka Estimation

1.4K
This lesson introduces two critical methods in pharmacokinetics, the Wagner-Nelson and Loo-Riegelman methods, used for estimating the absorption rate constant (ka) for drugs administered via non-intravenous routes. The Wagner-Nelson method relates ka to the plasma concentration derived from the slope of a semilog percent unabsorbed time plot. However, it is limited to drugs with one-compartment kinetics and can be impacted by factors like gastrointestinal motility or enzymatic degradation.
On...
1.4K
Linear Approximation in Frequency Domain01:26

Linear Approximation in Frequency Domain

423
Linear systems are characterized by two main properties: superposition and homogeneity. Superposition allows the response to multiple inputs to be the sum of the responses to each individual input. Homogeneity ensures that scaling an input by a scalar results in the response being scaled by the same scalar.
In contrast, nonlinear systems do not inherently possess these properties. However, for small deviations around an operating point, a nonlinear system can often be approximated as linear....
423
Linear Approximation in Time Domain01:21

Linear Approximation in Time Domain

394
Nonlinear systems often require sophisticated approaches for accurate modeling and analysis, with state-space representation being particularly effective. This method is especially useful for systems where variables and parameters vary with time or operating conditions, such as in a simple pendulum or a translational mechanical system with nonlinear springs.
For a simple pendulum with a mass evenly distributed along its length and the center of mass located at half the pendulum's length,...
394

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Mitochondrial heteroplasmy-phenotype correlation and response to glucose lowering therapy in subjects with m.3243A>G mutations.

Diabetes & metabolism·2025
Same author

tRNA-derived fragments are altered in diabetes.

Diabetic medicine : a journal of the British Diabetic Association·2023
Same author

Evaluating the performance of the GeneXpert HIV-1 qualitative assay as a consecutive test for a new early infant diagnosis algorithm in South Africa.

South African medical journal = Suid-Afrikaanse tydskrif vir geneeskunde·2021
Same author

Using localized Twitter activity to assess harmful algal bloom impacts of Karenia brevis in Florida, USA.

Harmful algae·2021
Same author

An experimental investigation to model wheezing in lungs.

Royal Society open science·2021
Same author

A Metabolic Intravascular Platform to Study FDG Uptake in Vascular Injury.

Cardiovascular engineering and technology·2020

Related Experiment Video

Updated: Mar 21, 2026

Utilizing vmTracking to Improve the Accuracy of Multi-Animal Pose Estimation in Rodent Social Behavior Studies
07:34

Utilizing vmTracking to Improve the Accuracy of Multi-Animal Pose Estimation in Rodent Social Behavior Studies

Published on: November 7, 2025

454

Estimating missing marker positions using low dimensional Kalman smoothing.

M Burke1, J Lasenby2

  • 1University of Cambridge, Cambridge CB2 1PZ, UK; Mobile Intelligent Autonomous Systems, Council for Scientific and Industrial Research, Pretoria, South Africa.

Journal of Biomechanics
|May 9, 2016
PubMed
Summary
This summary is machine-generated.

This study introduces a novel marker completion algorithm for motion capture, combining dynamical modeling and matrix completion. This approach accurately estimates missing marker positions without prior knowledge, overcoming limitations of existing methods.

Keywords:
Kalman filterMissing markersMotion captureSVD

More Related Videos

Estimation of Contact Regions Between Hands and Objects During Human Multi-Digit Grasping
09:41

Estimation of Contact Regions Between Hands and Objects During Human Multi-Digit Grasping

Published on: April 21, 2023

2.3K
Sit-to-stand-and-walk from 120% Knee Height: A Novel Approach to Assess Dynamic Postural Control Independent of Lead-limb
08:24

Sit-to-stand-and-walk from 120% Knee Height: A Novel Approach to Assess Dynamic Postural Control Independent of Lead-limb

Published on: August 30, 2016

10.8K

Related Experiment Videos

Last Updated: Mar 21, 2026

Utilizing vmTracking to Improve the Accuracy of Multi-Animal Pose Estimation in Rodent Social Behavior Studies
07:34

Utilizing vmTracking to Improve the Accuracy of Multi-Animal Pose Estimation in Rodent Social Behavior Studies

Published on: November 7, 2025

454
Estimation of Contact Regions Between Hands and Objects During Human Multi-Digit Grasping
09:41

Estimation of Contact Regions Between Hands and Objects During Human Multi-Digit Grasping

Published on: April 21, 2023

2.3K
Sit-to-stand-and-walk from 120% Knee Height: A Novel Approach to Assess Dynamic Postural Control Independent of Lead-limb
08:24

Sit-to-stand-and-walk from 120% Knee Height: A Novel Approach to Assess Dynamic Postural Control Independent of Lead-limb

Published on: August 30, 2016

10.8K

Area of Science:

  • Biomechanics
  • Motion Capture Technology
  • Human Motion Analysis

Background:

  • Motion capture is vital for biomechanics and human motion studies.
  • Marker occlusion or loss in motion capture systems presents a significant challenge.
  • Accurate estimation of missing marker positions is crucial for reliable data.

Purpose of the Study:

  • To develop an effective marker completion algorithm for motion capture.
  • To address the challenge of estimating missing marker positions without prior marker placement knowledge.
  • To improve the accuracy and robustness of motion capture data.

Main Methods:

  • Combining dynamical modeling-based tracking approaches with low-rank matrix completion.
  • Developing a hybrid algorithm for marker position estimation.
  • Evaluating the algorithm's performance in scenarios with occluded or missing markers.

Main Results:

  • The combined approach significantly outperforms individual tracking and matrix completion methods.
  • The algorithm successfully estimates missing marker positions even without prior knowledge.
  • Incremental position errors, common in tracking methods, are effectively resolved.

Conclusions:

  • A novel hybrid marker completion algorithm offers superior performance in motion capture.
  • This method enhances the reliability of biomechanical analyses by addressing marker occlusion.
  • The findings have implications for improving human motion studies and related fields.