Motion-Correction Enabled Ultra-High Resolution In-Vivo 7T-MRI of the Brain

Christian Federau1, Daniel Gallichan2

  • 1Dept of Radiology, Section of Neuroradiology, Stanford University, Stanford, California, United States of America.

Plos One
|May 10, 2016
PubMed
Abstract

Related Concept Videos

Pulmonary Structural MRI using Free-Breathing, Self-Gated Ultra-short Echo Time Imaging05:07

Pulmonary Structural MRI using Free-Breathing, Self-Gated Ultra-short Echo Time Imaging

A protocol is described for generating high-resolution structural images of the lungs using ultra-short-echo time (UTE) Magnetic Resonance Imaging (MRI). This protocol allows for images to be acquired using a simple MRI pulse sequence during free-breathing.
717
Measuring the Influence of Magnetic Vestibular Stimulation on Nystagmus, Self-Motion Perception, and Cognitive Performance in a 7T MRT08:57

Measuring the Influence of Magnetic Vestibular Stimulation on Nystagmus, Self-Motion Perception, and Cognitive Performance in a 7T MRT

In this article, we describe the experimental setup, material, and procedures to assess reflexive eye movements, self-motion perception, and cognitive tasks under magnetic vestibular stimulation, as well as the anatomical orientation of the vestibular organs, in a 7 Tesla Magnetic resonance tomography (7T-MRT)...
2.4K
High-resolution Structural Magnetic Resonance Imaging of the Human Subcortex In Vivo and Postmortem08:16

High-resolution Structural Magnetic Resonance Imaging of the Human Subcortex In Vivo and Postmortem

Here we present a protocol to determine the minimum number images that needed to be registered and averaged to resolve subcortical structures and test whether the individual layers of the LGN could be resolved in the absence of physiological noise.
15.8K
Use of Ultra-high Field MRI in Small Rodent Models of Polycystic Kidney Disease for In Vivo Phenotyping and Drug Monitoring07:35

Use of Ultra-high Field MRI in Small Rodent Models of Polycystic Kidney Disease for In Vivo Phenotyping and Drug Monitoring

The use of ultra-high field MRI as a non-invasive way to obtain phenotypic information of rodent models for polycystic kidney disease and to monitor interventions is described. Compared with the traditional histological approach, MRI images can be acquired in vivo, allowing for longitudinal...
11.9K
In vivo 19F MRI for Cell Tracking10:05

In vivo 19F MRI for Cell Tracking

We describe a general protocol for in vivo cell tracking using MRI in a mouse model with ex vivo labeled cells. A typical protocol for cell labeling, image acquisition processing and quantification is...
15.4K
NMR Spectrometers: Resolution and Error Correction01:14

NMR Spectrometers: Resolution and Error Correction

When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...
1.0K