In vivo Raman Microspectroscopy: Intra- and Intersubject Variability of Stratum Corneum Spectral Markers
Alessia Quatela1, Lynda Miloudi, Ali Tfayli
1Laboratory of Lipids: Analytical and Biological Systems Lip(Sys)2, Group of Analytical Chemistry of Paris-Sud (GCAPS), University Paris Sud, Universitx00E9; Paris-Saclay, Chx00E2;tenay-Malabry, France.
Background:
In vivo Raman spectroscopy is a powerful tool for real-time analysis and in situ evaluation of tissues such as the skin. The efficiency of this technique has been widely demonstrated as a label-free method for in vivo evaluation of the skin. The aim of this study is to gather information about inter- and intra-individual variations in the spectral descriptors of water content and structure, organization of the lipid barrier and structure of proteins in the stratum corneum (SC).
Methods:
In vivo SC measurements were performed on 17 female volunteers aged 20-30 years (phototypes I and II). For intra-individual variability, spectral collection was performed on 5 successive days per volunteer. Shapiro-Wilk and Cochran tests were applied to check the normality and the homoscedasticity of variances. ANOVA was then applied to evaluate intra- and intergroup variability.
Results:
ANOVA was performed on the spectral descriptors of water content and structure, organization of the lipid barrier and secondary structure of proteins in the SC. No significant intra- and interday variability was observed for all volunteers. Despite the low value of the total relative standard deviation, a highly significant variation was observed between volunteers.
Conclusion:
Interindividual variability for Raman measurements is significant for a set of volunteers with normal nondiseased SC and close phototypes. This variability should be taken into consideration as a threshold for significant variance when working in vivo.
Related Concept Videos
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Reticular Dermis
Reticular Layer
Underlying the papillary layer is the much thicker reticular layer, composed of dense, irregular connective...