Related Experiment Video
Updated: Mar 21, 2026

Hemocompatibility Testing of Blood-Contacting Implants in a Flow Loop Model Mimicking Human Blood Flow
Published on: March 5, 2020
Lack of Concordance Between Local Investigators, Angiographic Core Laboratory, and Clinical Event Committee in the
Christopher J Popma1, Shi Sheng1, Serge Korjian1
1From the Division of Cardiology, Department of Medicine, Beth Israel Deaconess Medical Center, Boston, MA (C.J.P., S.K., Y.D., G.C., C.M.G.); Department of Vascular Surgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China (S.S.); Duke Clinical Research Institute, Durham, NC (P.T., Z.H.); Department of Medicine, Gill Heart Institute, University of Kentucky, Lexington (D.J.M.); Department of Cardiology, Green Lane Cardiovascular Service, Auckland City Hospital, Auckland, New Zealand (H.D.W.); Department of Cardiology, University of Leuven, Leuven, Belgium (F.V.d.W.); Department of Medicine, Stanford University, CA (R.A.H., K.W.M.); Department of Medical Sciences, Cardiology, and Uppsala Clinical Research Center, Uppsala University, Uppsala, Sweden (L.W., C.H.); Division of Cardiology, Department of Medicine, University of Alberta, Edmonton, Canada (P.W.A.); Cardiac and Critical Care Services, Department of Medicine, South Australian Health and Medical Research Institute, Flinders University and Medical Centre, Adelaide, Australia (P.E.A.); and Merck Clinical Research, Merck & Co, Whitehouse Station, NJ (J.S.).
Insights
Stent thrombosis adjudication varies significantly between local investigators, clinical event committees, and angiographic core laboratories. Direct angiogram review by core laboratories more frequently detects stent thrombosis.
Area of Science:
- Cardiology
- Clinical Trials
- Medical Imaging
Background:
- Stent thrombosis (ST) is a critical endpoint in cardiovascular trials.
- Traditional ST adjudication relies on clinical event committee (CEC) review, not angiograms.
- Variability in ST assessment between different review methods is unstudied.
Purpose of the Study:
- To assess the concordance of stent thrombosis (ST) adjudication among local investigators (LIs), a clinical event committee (CEC), and an independent angiographic core laboratory (ACL).
Main Methods:
- Serial angiograms from 329 patients in the TRACER trial with possible ST were reviewed by an ACL.
- The ACL was blinded to LI and CEC assessments.
- CEC adjudication used Academic Research Consortium definitions based on case report forms and source documents.
Main Results:
- Overall agreement on ST presence/absence among ACL, CEC, and LIs was low (52.9%, κ=0.32).
- Agreement between ACL and CEC was higher (82.7%, κ=0.57).
- Agreement between ACL and LIs (61.1%) and CEC and LIs (62%) was also limited.
Conclusions:
- Stent thrombosis reporting is discordant among ACL, CEC, and LIs.
- Angiographic core laboratory review of angiograms detects ST more often.
Background:
Stent thrombosis (ST) is an important end point in cardiovascular clinical trials. Adjudication is traditionally based on clinical event committee (CEC) review of case report forms and source documentation rather than angiograms. However, the degree to which this method of adjudication is concordant with the review of independent angiographic core laboratories (ACLs) has not been studied. This report represents the first assessment of variability between local investigators (LIs), a CEC, and an ACL.
Methods And Results:
Serial angiograms of 329 patients with acute coronary syndrome without ST-segment-elevation who underwent percutaneous coronary intervention at entry in the Trial to Assess the Effects of Vorapaxar in Preventing Heart Attack and Stroke in Particpants With Acute Coronary Syndrome (TRACER) and who met criteria for possible ST subsequent to the index event were reviewed by an ACL. The ACL was blinded to the assessment by both LIs and the CEC regarding the presence or absence of ST. CEC adjudication was based on Academic Research Consortium definitions of ST, using case report form data and source documents, including catheterization laboratory reports. The ACL, CEC, and LIs agreed on the presence or absence of ST in 52.9% events (κ=0.32; 95% confidence interval, 0.26-0.39). The ACL and CEC agreed on 82.7% of events (κ=0.57; 95% confidence interval, 0.47-0.67); the ACL and LIs agreed on 61.1% of events (κ=0.25; 95% confidence interval, 0.16-0.34); and the CEC and LIs agreed on 62% of events (κ=0.28; 95% confidence interval, 0.21-0.36).
Conclusions:
ST reporting by an ACL, a CEC, and LIs is discordant. The assessment of ST is more often detected by direct review of angiograms by an ACL.
Clinical Trial Registration:
URL: http://www.clinicaltrials.gov. Unique identifier: NCT00527943.
More Related Videos
Related Concept Videos
Acute Coronary Syndrome III: Diagnostic Studies
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care
Acute Coronary Syndrome II: Pathophysiology and Clinical Manifestations
Aneurysm II: Clinical Manifestations and Diagnostic Studies