Accuracy of First- and Second-Generation Colon Capsules in Endoscopic Detection of Colorectal Polyps: A Systematic Review and Meta-analysis
Related Experiment Video
Updated: Mar 21, 2026

Flexible Colonoscopy in Mice to Evaluate the Severity of Colitis and Colorectal Tumors Using a Validated Endoscopic Scoring System
Published on: October 16, 2013
Cristiano Spada1, Shabana F Pasha2, Seth A Gross3
1Digestive Endoscopy Unit, Fondazione Policlinico Universitario "A. Gemelli", Rome, Italy.
Background & Aims:
Colon capsule endoscopy (CCE) is a noninvasive technique used to explore the colon without sedation or air insufflation. A second-generation capsule was recently developed to improve accuracy of detection, and clinical use has expanded globally. We performed a systematic review and meta-analysis to assess the accuracy of CCE in detecting colorectal polyps.
Methods:
We searched MEDLINE, EMBASE, Cochrane Central Register of Controlled Trials, and other databases from 1966 through 2015 for studies that compared accuracy of colonoscopy with histologic evaluation with CCE. The risk of bias within each study was ascertained according to Quality Assessment of Diagnostic Accuracy in Systematic Reviews recommendations. Per-patient accuracy values were calculated for polyps, overall and for first-generation (CCE-1) and second-generation (CCE-2) capsules. We analyzed data by using forest plots, the I2 statistic to calculate heterogeneity, and meta-regression analyses.
Results:
Fourteen studies provided data from 2420 patients (1128 for CCE-1 and 1292 for CCE-2). CCE-2 and CCE-1 detected polyps >6 mm with 86% sensitivity (95% confidence interval [CI], 82%-89%) and 58% sensitivity (95% CI, 44%-70%), respectively, and 88.1% specificity (95% CI, 74.2%-95.0%) and 85.7% specificity (95% CI, 80.2%-90.0%), respectively. CCE-2 and CCE-1 detected polyps >10 mm with 87% sensitivity (95% CI, 81%-91%) and 54% sensitivity (95% CI, 29%-77%), respectively, and 95.3% specificity (95% CI, 91.5%-97.5%) and 97.4% specificity (95% CI, 96.0%-98.3%), respectively. CCE-2 identified all 11 invasive cancers detected by colonoscopy.
Conclusions:
The sensitivity in detection of polyps >6 mm and >10 mm increased substantially between development of first-generation and second-generation colon capsules. High specificity values for detection of polyps by CCE-2 seem to be achievable with a 10-mm cutoff and in a screening setting.
Related Concept Videos
Endoscopic Procedures III: Video Capsule Endoscopy
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Endoscopic Procedures II: Colonoscopy
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...

