Related Experiment Video
Updated: Mar 21, 2026

An Application for Pairing with Wearable Devices to Monitor Personal Health Status
Published on: February 3, 2022
Comparison of smartphone application-based vital sign monitors without external hardware versus those used in
John C Alexander1, Abu Minhajuddin2, Girish P Joshi3
1Department of Anesthesiology and Pain Management, University of Texas Southwestern Medical Center, 5323 Harry Hines Blvd., Dallas, TX, 75390-9068, USA. john.alexander@utsouthwestern.edu.
Abstract:
Use of healthcare-related smartphone applications is common. However, there is concern that inaccurate information from these applications may lead patients to make erroneous healthcare decisions. The objective of this study is to study smartphone applications purporting to measure vital sign data using only onboard technology compared with monitors used routinely in clinical practice. This is a prospective trial comparing correlation between a clinically utilized vital sign monitor (Propaq CS, WelchAllyn, Skaneateles Falls, NY, USA) and four smartphone application-based monitors Instant Blood Pressure, Instant Blood Pressure Pro, Pulse Oximeter, and Pulse Oximeter Pro. We performed measurements of heart rate (HR), systolic blood pressures (SBP), diastolic blood pressure (DBP), and oxygen saturation (SpO2) using standard monitor and four smartphone applications. Analysis of variance was used to compare measurements from the applications to the routine monitor. The study was completed on 100 healthy volunteers. Comparison of routine monitor with the smartphone applications shows significant differences in terms of HR, SpO2 and DBP. The SBP values from the applications were not significantly different from those from the routine monitor, but had wide limits of agreement signifying a large degree of variation in the compared values. The degree of correlation between monitors routinely used in clinical practice and the smartphone-based applications studied is insufficient to recommend clinical utilization. This lack of correlation suggests that the applications evaluated do not provide clinically meaningful data. The inaccurate data provided by these applications can potentially contribute to patient harm.
Related Concept Videos
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Holter Monitor: 24-Hour Monitoring
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Introduction to Vital Signs
Vital signs help healthcare professionals assess an individual's well-being and detect any functional changes...

