A Novel Calibration-Minimum Method for Prediction of Mole Fraction in Non-Ideal Mixture

Shojiro Shibayama1, Hiromasa Kaneko1, Kimito Funatsu2

  • 1Department of Chemical System Engineering, The University of Tokyo, 7-3-1, Hongo, Bunkyo-ku, Tokyo, 113-8656, Japan.

AAPS Pharmscitech
|May 13, 2016
PubMed

Related Concept Videos

Calibration Curves: Linear Least Squares01:20

Calibration Curves: Linear Least Squares

A calibration curve is a plot of the instrument's response against a series of known concentrations of a substance. This curve is used to set the instrument response levels, using the substance and its concentrations as standards. Alternatively, or additionally, an equation is fitted to the calibration curve plot and subsequently used to calculate the unknown concentrations of other samples reliably.
For data that follow a straight line, the standard method for fitting is the linear...
5.1K
Instrument Calibration01:12

Instrument Calibration

Instrument calibration is essential for ensuring that instruments produce accurate and consistent results. It is vital in manufacturing, healthcare, testing laboratories, and scientific research. Calibration processes are specific to each instrument and help enhance data accuracy. Each instrument has a unique calibration process tailored to its design and function to improve data accuracy.
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
1.1K
Glassware Calibration01:11

Glassware Calibration

Accurate calibration of glassware, such as volumetric flasks, pipettes, and burettes, is essential to ensure accurate measurements in the analytical laboratory. Calibration helps maintain consistency across measurements and prevents errors arising from inaccurate volumes.
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
1.9K
Nonideal Two-Component Liquid Solutions01:29

Nonideal Two-Component Liquid Solutions

Nonideal liquid solutions, also known as real solutions, do not strictly follow Raoult's law. Raoult's law is a rule of thumb in physical chemistry. However, not all mixtures adhere to this law due to varying molecular interactions. For example, in an acetone/chloroform solution, the individual vapor pressures of the components are lower than expected, resulting in a total vapor pressure below that predicted by Raoult's law, causing a negative deviation.On the other hand, in an ethanol/water...
52
Ideal Solutions or Mixtures01:20

Ideal Solutions or Mixtures

From a molecular perspective, an ideal solution is one in which the intermolecular interactions between unlike molecules are, on average, the same as those between like molecules. This is the case for ideal gas mixtures, where the molecules are far apart and do not interact with each other. However, for condensed phases like liquids or solids, the molecules are close together and interact with each other. In an ideal solution, the molecules of different species are so similar to each other that...
59
The Small x Assumption02:20

The Small x Assumption

If a reaction has a small equilibrium constant, the equilibrium position favors the reactants. In such reactions, a negligible change in concentration may occur if the initial concentrations of reactants are high and the Kc value is small. In such circumstances, the equilibrium concentration is approximately equal to its initial concentration.  This estimation can be used to simplify the equilibrium calculations by assuming that some equilibrium concentrations are equal to the initial...
50.6K