Related Experiment Video
Updated: Mar 21, 2026

Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
Complications and functional outcome after fixation of distal tibia fractures with locking plate - A multicentre
Bjarke Viberg1, Silje Kleven1, Ellen Hamborg-Petersen1
1Department of Orthopaedic Surgery and Traumatology, Odense University Hospital, Denmark.
Introduction:
The aim of this study was to evaluate the proportion of complications and the functional outcome following ORIF with low-profile locking plates in patients with distal tibia fractures.
Method:
Retrospective data was retrieved using county databases, operation books, health record and X-ray images for 6 hospitals (1 level 1, 5 level 2) in the Region of Southern Denmark. Between January 2007 and April 2011 70 consecutive patients with 71 distal tibia fractures were treated with low-profile locking plate were included. The proportion of post-operative complications, classified as minor and major complications, was retrieved from electronic health records and patient interviews. Long-term functional outcome assessed by EuroQol EQ-5D-5L questionnaire, AOFAS Ankle-Hindfoot scale, and return to pre-injury job function through patient interview and examination.
Results:
There were 32 43A, 5 43B and 34 43C-fractures, 12 open and 10 high-energy fractures. Forty-nine cases (69%) experienced complications during the follow-up time, of which 34 were minor complications and 15 were major complications. Median EQ-5D-5L index value was 0.76, median EQ VAS-score was 80, and median AOFAS score was 73. Thirty-three percent of working patients had not returned to work as a result of the fracture.
Conclusions:
Our study suggest that treatment of distal tibia fractures with low-profile locking plates might have a higher proportion of complications and worse functional outcome than previously reported.
Level Of Evidence:
Therapeutic level IV Case Serie.