Related Experiment Video
Updated: Mar 21, 2026

Leaf Spray Mass Spectrometry: A Rapid Ambient Ionization Technique to Directly Assess Metabolites from Plant Tissues
Published on: June 21, 2018
Interlayer spray ionization mass spectrometry for the simple direct analysis of low amounts of sample
Jin Chen1, Fei Tang2, Cheng'an Guo1
1State Key Laboratory of Precision Measurement Technology and Instruments, Department of Precision Instrument, Tsinghua University, Beijing, 100084, China.
Abstract:
Interlayer spray is proposed as a convenient ionization source for direct analysis by mass spectrometry. Two slices of non-absorbent substrate hold the liquid sample to form a sandwich structure. By applying a high voltage to the sample, spray is generated at the tip of the substrate. The sampling procedure can be operated easily in an open condition and the spray is processed in a semi-enclosed condition, which leads to a relatively stable process. An ultralow amount (<2 μL) of the liquid sample can be analyzed without dilution, which ensures that the natural concentration and properties of the target are maintained. Less influence from the substrate is achieved compared with the spray methods based on porous absorbent materials, which results in a sensitivity enhancement of large molecule samples. It is demonstrated that the interlayer spray is applicable for the analysis of various compounds, including therapeutic drugs, peptides, and proteins. Good linearity can be obtained at a concentration as low as 50 ng/mL in the quantitative analysis for imatinib. We also show the ability to identify the chemical residuals on surfaces with high sensitivity by the "wipe-spray" method, which is useful for the fast screening of illicit substances. Interlayer spray working with mass spectrometry provides a promising method for direct analysis in an ambient environment. Graphical Abstract The schematic of the interlayer spray ionization source.
More Related Videos
09:22Atmospheric-pressure Molecular Imaging of Biological Tissues and Biofilms by LAESI Mass Spectrometry
Published on: September 3, 2010
05:48Analysis of Volatile and Oxidation Sensitive Compounds Using a Cold Inlet System and Electron Impact Mass Spectrometry
Published on: September 5, 2014
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Chemical Ionization (CI) Mass Spectrometry
MALDI-TOF Mass Spectrometry
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Matrix-Assisted Laser Desorption Ionization (MALDI)