Related Experiment Video
Updated: Mar 21, 2026

Dual-mode Imaging of Cutaneous Tissue Oxygenation and Vascular Function
Published on: December 8, 2010
Detection of Endothelial Dysfunction Using Skin Temperature Oscillations Analysis During Local Heating in Patients
Aleksey Parshakov1,2, Nadezhda Zubareva1,2, Sergey Podtaev2
1Perm State Medical University, Perm, Russia.
Objective:
The purpose of this study was to examine correlations between laboratory markers of ED and the degree of endothelium-dependent vasodilation using WAST during a local heating test in patients with PAD.
Materials And Methods:
The study population consisted of 17 healthy subjects and 38 patients with PAD. The ST on the plantar surface of the first toe was measured during the test, and the inverse wavelet transform was applied to reconstruct the ST signals in three frequency bands corresponding to myogenic, neurogenic, and endothelial mechanisms of vascular tone regulation.
Results:
In healthy subjects, a local increase in temperature of up to 42°C caused a greater than threefold increase in the amplitudes of foot ST oscillations. Among patients with PAD, the response to the test was much weaker in all frequency ranges. The level of vasodilation dysfunction correlated with the level of artery stenosis in the lower extremities and with laboratory markers of ED (endothelin, homocysteine, and von Willebrand factor).
Conclusion:
WAST can be considered as a low cost, portable, and easy to use technique for the noninvasive assessment of ED.
More Related Videos
08:21Author Spotlight: A Pharmacodissection Approach to Uncover Mechanisms in Cardiovascular Disease Risk Populations
Published on: July 21, 2023
04:44Author Spotlight: Enhancing Vascular Function and Physical Capacity in Cardiovascular Disease Through Novel Interventions and NIRS Technology
Published on: March 22, 2024
Related Concept Videos
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Peripheral Artery Disease IV: Nursing Management
Atherosclerosis II: Clinical Manifestations and Diagnostic Tests