Related Experiment Video
Updated: Mar 21, 2026

Using Extraordinary Optical Transmission to Quantify Cardiac Biomarkers in Human Serum
Published on: December 13, 2017
The Use of Very Low Concentrations of High-sensitivity Troponin T to Rule Out Acute Myocardial Infarction Using a
Richard Body1,2, Christian Mueller3, Evangelos Giannitsis4
1Emergency Department, Central Manchester University Hospitals NHS Foundation Trust, Manchester Academic Health Sciences Centre, Manchester, United Kingdom. richard.body@manchester.ac.uk.
Background:
Recent single-center and retrospective studies suggest that acute myocardial infarction (AMI) could be immediately excluded without serial sampling in patients with initial high-sensitivity cardiac troponin T (hs-cTnT) levels below the limit of detection (LoD) of the assay and no electrocardiogram (ECG) ischemia.
Objective:
We aimed to determine the external validity of those findings in a multicenter study at 12 sites in nine countries.
Methods:
TRAPID-AMI was a prospective diagnostic cohort study including patients with suspected cardiac chest pain within 6 hours of peak symptoms. Blood drawn on arrival was centrally tested for hs-cTnT (Roche; 99th percentile = 14 ng/L, LoD = 5 ng/L). All patients underwent serial troponin sampling over 4-14 hours. The primary outcome, prevalent AMI, was adjudicated based on sensitive troponin I (Siemens Ultra) levels. Major adverse cardiac events (MACE) including AMI, death, or rehospitalization for acute coronary syndrome with coronary revascularization were determined after 30 days.
Results:
We included 1,282 patients, of whom 213 (16.6%) had AMI and 231 (18.0%) developed MACE. Of 560 (43.7%) patients with initial hs-cTnT levels below the LoD, four (0.7%) had AMI. In total, 471 (36.7%) patients had both initial hs-cTnT levels below the LoD and no ECG ischemia. These patients had a 0.4% (n = 2) probability of AMI, giving 99.1% (95% confidence interval [CI] = 96.7% to 99.9%) sensitivity and 99.6% (95% CI = 98.5% to 100.0%) negative predictive value. The incidence of MACE in this group was 1.3% (95% CI = 0.5% to 2.8%).
Conclusions:
In the absence of ECG ischemia, the detection of very low concentrations of hs-cTnT at admission seems to allow rapid, safe exclusion of AMI in one-third of patients without serial sampling. This could be used alongside careful clinical assessment to help reduce unnecessary hospital admissions.
More Related Videos
10:12A Sensitive and Specific Quantitation Method for Determination of Serum Cardiac Myosin Binding Protein-C by Electrochemiluminescence Immunoassay
Published on: August 8, 2013
07:40Impact of High-intensity Interval Exercise and Moderate-Intensity Continuous Exercise on the Cardiac Troponin T Level at an Early Stage of Training
Published on: October 10, 2019
Related Concept Videos
Blood Studies for Cardiovascular System I: Cardiac Biomarkers
The essential diagnostic tools for detecting myocardial necrosis and monitoring individuals suspected of having acute coronary syndrome (ACS) include:
Troponins
Troponins, particularly cardiac troponins I and T, are the most precise and sensitive markers of myocardial injury. They are detectable within 4-6 hours of myocardial injury and remain...
Acute Coronary Syndrome III: Diagnostic Studies
Acute Coronary Syndrome I: Introduction
Myocarditis II: Clinical Features and Diagnostic Tests
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes