Objective:
This cross-sectional study assessed the ability of standard EEG in distinguishing vegetative state (VS) from minimally conscious state plus (MCS+) or MCS minus (MCS-), and to correlate EEG features with aetiology and level of responsiveness assessed by Coma Recovery Scale-Revised (CRS-R).
Methods:
We analyzed background EEG activity and EEG reactivity to eye opening and closing and to tactile, acoustic, nociceptive stimuli and Intermittent Photic Stimulation (IPS) in 73 inpatients (VS=37, MCS-=11, MCS+=25), with traumatic (n=21), vascular (n=25) or anoxic (n=27) aetiology.
Results:
All patients, but one, showed abnormal background activity. EEG abnormalities were more severe in VS than in MCS+ or MCS-, and in anoxic than other aetiologies. MCS+ patients with normal or Mildly Abnormal background activity showed higher scores on CRS-R than patients with moderate to severe EEG abnormalities. Reactivity to IPS, and acoustic stimuli was significantly more frequent in MCS+ and MCS- than in VS patients.
Conclusions:
EEG features differ between VS and MCS- or MCS+ patients and can provide evidence of relative sparing of thalamocortical connections in MCS+ patients. In anoxic patients EEG organization is more severely impaired and provides less discriminative diagnostic information.
Significance:
Conventional EEG can help clinicians to disentangle VS from MCS patients.