Related Experiment Video
Updated: Mar 21, 2026

Uracil-DNA Glycosylase Assay by Matrix-assisted Laser Desorption/Ionization Time-of-flight Mass Spectrometry Analysis
Published on: April 22, 2022
Development and validation of a rapid and sensitive UPLC-MS/MS method for determination of uracil and dihydrouracil
Bart A W Jacobs1, Hilde Rosing2, Niels de Vries2
1The Netherlands Cancer Institute, Department of Clinical Pharmacology, Plesmanlaan 121, 1066 CX, Amsterdam, The Netherlands; The Netherlands Cancer Institute, Department of Pharmacy and Pharmacology, Louwesweg 6, 1066 EC, Amsterdam, The Netherlands.
Abstract:
Quantification of the endogenous dihydropyrimidine dehydrogenase (DPD) substrate uracil (U) and the reaction product dihydrouracil (UH2) in plasma might be suitable for identification of patients at risk of fluoropyrimidine-induced toxicity as a result of DPD deficiency. In this paper, we describe the development and validation of a rapid and sensitive ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) assay for quantification of U and UH2 in human plasma. Analytes were extracted by protein precipitation, chromatographically separated on an Acquity UPLC(®) HSS T3 column with gradient elution and analyzed with a tandem mass spectrometer equipped with an electrospray ionization source. U was quantified in the negative ion mode and UH2 in the positive ion mode. Stable isotopes for U and UH2 were used as internal standards. Total chromatographic run time was 5min. Validated concentration ranges for U and UH2 were from 1 to 100ng/mL and 10 to 1000ng/mL, respectively. Inter-assay bias and inter-assay precision for U were within ±2.8% and ≤12.4%. For UH2, inter-assay bias and inter-assay precision were within ±2.9% and ≤7.2%. Adequate stability of U and UH2 in dry extract, final extract, stock solution and plasma was demonstrated. Stability of U and UH2 in whole blood was only satisfactory when stored up to 4hours at 2-8°C, but not at ambient temperatures. An accurate, precise and sensitive UPLC-MS/MS assay for quantification of U and UH2 in plasma was developed. This assay is now applied to support clinical studies with fluoropyrimidine drugs.
More Related Videos
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
11:00Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry UPLC-HRMS
Published on: May 20, 2013